Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1996 |
Principal Product | Business Cards, Labels, and Letterheads |
NAICS | n/a |
SIC | 2799 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 591 |
Plant Area (Sq.Ft.) | 170,000 |
Annual Production | 608,000 Pieces |
Production Hrs. Annual | 6,550 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $89,630 | 3,934,056 | kWh | $0.02 |
Electricity Demand | $77,694 | 8,742 | kW-months/year | $8.89 |
TOTAL ENERGY COSTS | $185,924 | |||
RECOMMENDED SAVINGS* | $57,728 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,323 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $100 Cost: $3,020 |
$32 | 1,465 | $68 | 8 | - | - | - | - | - | - |
$32 1,465 kWh |
$68 8 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $5,423 Cost: $6,179 |
- | - | $5,423 | - | - | - | - | - | - | - |
- - kWh |
$5,423 - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $195 Cost: $20 |
$62 | 2,638 | $133 | 15 | - | - | - | - | - | - |
$62 2,638 kWh |
$133 15 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $1,860 Cost: - |
- | - | - | - | $1,860 | 10,400 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,860 10,400 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $20,800 Cost: - |
- | - | - | - | - | - | - | - | $20,800 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$20,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7134 WASH AND REUSE RAGS ON-SITE |
Savings: $29,350 Cost: $4,300 |
- | - | - | - | - | - | $29,350 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$29,350 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $57,728 Cost: $13,519 |
$94 | 4,103 | $5,624 | 23 | $1,860 | 10,400 | $29,350 | - | $20,800 | - | $94 4,103 kWh |
$5,624 23 kW-months/year |
$1,860 10,400 lb |
$29,350 - $ |
$20,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,323 Cost: $9,199 |
$32 | 1,465 | $5,491 | 8 | - | - | - | - | $20,800 | - | $32 1,465 kWh |
$5,491 8 kW-months/year |
- - lb |
- - $ |
$20,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost |