Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1996 |
Principal Product | Organic and Inorganic Pigments |
NAICS | n/a |
SIC | 2865 - Cyclic Crudes And Intermediates |
Sales | $50,000,000-$100,000,000 |
# of Employees | 210 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 17,000,000 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $298,496 | 12,221,278 | kWh | $0.02 |
Electricity Demand | $150,892 | 22,656 | kW-months/year | $6.66 |
Natural Gas | $3,662 | 3,657 | MMBtu | $1.00 |
TOTAL ENERGY COSTS | $529,220 | |||
RECOMMENDED SAVINGS* | $254,295 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $600 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $195 Cost: $500 |
- | - | - | - | $195 | 195 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$195 195 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $990 Cost: $3,186 |
$697 | 28,429 | $293 | 44 | - | - | - | - | - | - | - | - |
$697 28,429 kWh |
$293 44 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $600 Cost: $9,340 |
$434 | 17,878 | $166 | 25 | - | - | - | - | - | - | - | - |
$434 17,878 kWh |
$166 25 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.7221 IMPROVE PROCESS CONTROL TO PREVENT SPILLS OF MATERIAL |
Savings: $199,480 Cost: $26,580 |
- | - | - | - | - | - | - | - | - | - | $199,480 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$199,480 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $16,140 Cost: $9,500 |
- | - | - | - | - | - | $16,140 | 78,500 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$16,140 78,500 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7134 WASH AND REUSE RAGS ON-SITE |
Savings: $1,860 Cost: $4,500 |
- | - | - | - | - | - | - | - | $1,860 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$1,860 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $22,850 Cost: - |
- | - | - | - | - | - | $22,850 | 76,170 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$22,850 76,170 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $12,180 Cost: - |
- | - | - | - | - | - | $12,180 | 60,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$12,180 60,000 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $254,295 Cost: $53,606 |
$1,131 | 46,307 | $459 | 69 | $195 | 195 | $51,170 | 214,670 | $1,860 | - | $199,480 | - | $1,131 46,307 kWh |
$459 69 kW-months/year |
$195 195 MMBtu |
$51,170 214,670 lb |
$1,860 - $ |
$199,480 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $600 Cost: $9,340 |
$434 | 17,878 | $166 | 25 | - | - | - | - | - | - | - | - | $434 17,878 kWh |
$166 25 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Primary Product |