Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1997 |
Principal Product | Letterpress and Lithographic Printing |
NAICS | n/a |
SIC | 2759 - Commercial Printing, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 69,790 |
Annual Production | 0 Pieces |
Production Hrs. Annual | 7,776 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $97,459 | 3,606,682 | kWh | $0.03 |
Electricity Demand | $73,434 | 7,638 | kW-months/year | $9.61 |
TOTAL ENERGY COSTS | $197,861 | |||
RECOMMENDED SAVINGS* | $422,588 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $802 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $802 Cost: $1,661 |
$444 | 16,413 | $358 | 37 | - | - | - | - | - | - | - | - | - | - |
$444 16,413 kWh |
$358 37 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $136 Cost: $3,180 |
$88 | 3,224 | $48 | 5 | - | - | - | - | - | - | - | - | - | - |
$88 3,224 kWh |
$48 5 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5121 RECYCLE WASTE INK AND CLEANUP SOLVENT |
Savings: $45,321 Cost: - |
- | - | - | - | $3,640 | 1,425 | - | - | - | - | $41,681 | - | - | - |
- - kWh |
- - kW-months/year |
$3,640 1,425 gal |
- - lb |
- - $ |
$41,681 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.231 PURCHASE EQUIPMENT INSTEAD OF LEASING |
Savings: $11,180 Cost: $4,500 |
- | - | - | - | - | - | - | - | $11,180 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
$11,180 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $9,373 Cost: $400 |
- | - | - | - | - | - | $373 | 60,000 | - | - | $9,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$373 60,000 lb |
- - $ |
$9,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $355,776 Cost: $77,600 |
- | - | - | - | - | - | - | - | - | - | - | - | $355,776 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
$355,776 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $422,588 Cost: $87,341 |
$532 | 19,637 | $406 | 42 | $3,640 | 1,425 | $373 | 60,000 | $11,180 | - | $50,681 | - | $355,776 | - | $532 19,637 kWh |
$406 42 kW-months/year |
$3,640 1,425 gal |
$373 60,000 lb |
$11,180 - $ |
$50,681 - $ |
$355,776 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $802 Cost: $1,661 |
$444 | 16,413 | $358 | 37 | - | - | - | - | - | - | - | - | - | - | $444 16,413 kWh |
$358 37 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Ancillary Material Cost |