Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 1997 |
Principal Product | Aluminum Foil |
NAICS | n/a |
SIC | 3353 - Aluminum Sheet, Plate, And Foil |
Sales | $100,000,000-$500,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 350,000 |
Annual Production | 120,000,000 Pounds |
Production Hrs. Annual | 6,864 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $666,786 | 26,803,928 | kWh | $0.02 |
Electricity Demand | $376,317 | 51,912 | kW-months/year | $7.25 |
Natural Gas | $76,491 | 18,861 | MMBtu | $4.06 |
TOTAL ENERGY COSTS | $1,119,594 | |||
RECOMMENDED SAVINGS* | $187,586 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $131,385 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,385 Cost: $2,200 |
$947 | 40,445 | $438 | 60 | - | - | - | - |
$947 40,445 kWh |
$438 60 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $151 Cost: $2,700 |
$100 | 4,103 | $51 | 7 | - | - | - | - |
$100 4,103 kWh |
$51 7 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $4,200 Cost: $260 |
$2,900 | 116,061 | $1,300 | 179 | - | - | - | - |
$2,900 116,061 kWh |
$1,300 179 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $11,650 Cost: $40 |
$8,050 | 323,271 | $3,600 | 497 | - | - | - | - |
$8,050 323,271 kWh |
$3,600 497 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $40,200 Cost: $82,600 |
- | - | - | - | $40,200 | 9,895 | - | - |
- - kWh |
- - kW-months/year |
$40,200 9,895 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.521 CLEAR AND RENT EXISTING SPACE |
Savings: $130,000 Cost: $2,400 |
- | - | - | - | - | - | $130,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$130,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $187,586 Cost: $90,200 |
$11,997 | 483,880 | $5,389 | 743 | $40,200 | 9,895 | $130,000 | - | $11,997 483,880 kWh |
$5,389 743 kW-months/year |
$40,200 9,895 MMBtu |
$130,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $131,385 Cost: $4,600 |
$947 | 40,445 | $438 | 60 | - | - | $130,000 | - | $947 40,445 kWh |
$438 60 kW-months/year |
- - MMBtu |
$130,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |