Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 1995
Principal Product Pressure Vessels
NAICS n/a
SIC 3443 - Fabricated Plate Work (boiler Shops)
Sales $5,000,000-$10,000,000
# of Employees 63
Plant Area (Sq.Ft.) 100,000
Annual Production 7,200 Pounds
Production Hrs. Annual 4,160
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $119,642 1,284,291 kWh $0.09
Natural Gas $41,669 9,530 MMBtu $4.37
TOTAL ENERGY COSTS $161,311
RECOMMENDED SAVINGS* $7,474 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,209
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,536
Cost:
$621
$1,536 16,413 - - $1,536
16,413
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,759
Cost:
$7,308
$1,759 20,223 - - $1,759
20,223
kWh
-
-
MMBtu
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$435
Cost:
-
$435 4,689 - - $435
4,689
kWh
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,294
Cost:
$150
$1,294 14,068 - - $1,294
14,068
kWh
-
-
MMBtu
05: 2.7441 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH Savings:
$2,450
Cost:
$2,000
- - $2,450 572 -
-
kWh
$2,450
572
MMBtu
TOTAL RECOMMENDED Savings:
$7,474
Cost:
$10,079
$5,024 55,393 $2,450 572 $5,024
55,393
kWh
$2,450
572
MMBtu
TOTAL IMPLEMENTED Savings:
$4,209
Cost:
$9,308
$1,759 20,223 $2,450 572 $1,759
20,223
kWh
$2,450
572
MMBtu
Savings
Cost
$ kWh $ MMBtu