Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 1996 |
Principal Product | Bakery Mixes |
NAICS | n/a |
SIC | 2041 - Flour And Other Grain Mill Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 130,850 |
Annual Production | 105,712,800 Pounds |
Production Hrs. Annual | 5,616 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $96,016 | 2,858,734 | kWh | $0.03 |
Electricity Demand | $71,690 | 8,059 | kW-months/year | $8.90 |
Electricity Fees | $11,227 | - | $ | - |
Natural Gas | $36,948 | 9,029 | MMBtu | $4.09 |
TOTAL ENERGY COSTS | $232,390 | |||
RECOMMENDED SAVINGS* | $18,634 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,817 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,306 Cost: $1,433 |
$1,008 | 16,120 | $298 | 38 | - | - | - | - |
$1,008 16,120 kWh |
$298 38 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,928 Cost: $245 |
$3,102 | 49,238 | $826 | 105 | - | - | - | - |
$3,102 49,238 kWh |
$826 105 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,568 Cost: $12,455 |
$922 | 14,654 | $646 | 82 | - | - | - | - |
$922 14,654 kWh |
$646 82 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,290 Cost: $500 |
$1,015 | 16,120 | $275 | 35 | - | - | - | - |
$1,015 16,120 kWh |
$275 35 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,105 Cost: $500 |
$4,116 | 65,358 | $989 | 126 | - | - | - | - |
$4,116 65,358 kWh |
$989 126 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1162 USE LESS WASTEFUL PACKAGING |
Savings: $817 Cost: - |
- | - | - | - | $400 | 10,950 | $417 | - |
- - kWh |
- - kW-months/year |
$400 10,950 lb |
$417 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $4,620 Cost: $1,500 |
- | - | - | - | $(-2,310) | 15,400 | $6,930 | - |
- - kWh |
- - kW-months/year |
$(-2,310) 15,400 lb |
$6,930 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,634 Cost: $16,633 |
$10,163 | 161,490 | $3,034 | 386 | $(-1,910) | 26,350 | $7,347 | - | $10,163 161,490 kWh |
$3,034 386 kW-months/year |
$(-1,910) 26,350 lb |
$7,347 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,817 Cost: $16,633 |
$10,163 | 161,490 | $3,034 | 386 | $(-2,310) | 15,400 | $6,930 | - | $10,163 161,490 kWh |
$3,034 386 kW-months/year |
$(-2,310) 15,400 lb |
$6,930 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material |