Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 1997 |
Principal Product | Envelopes |
NAICS | n/a |
SIC | 2699 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 115 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 700,000,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $85,432 | 2,886,284 | kWh | $0.03 |
Electricity Demand | $112,262 | 6,576 | kW-months/year | $17.07 |
Electricity Fees | $(-2,665) | - | $ | - |
Natural Gas | $4,371 | 1,009 | MMBtu | $4.33 |
TOTAL ENERGY COSTS | $202,820 | |||
RECOMMENDED SAVINGS* | $35,385 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,581 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes | Primary Raw Material | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $12,562 Cost: $7,260 |
$8,751 | 167,057 | $3,811 | 267 | - | - | - | - | - | - | - | - |
$8,751 167,057 kWh |
$3,811 267 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,062 Cost: $24,775 |
$7,915 | 127,491 | $4,147 | 291 | - | - | - | - | - | - | - | - |
$7,915 127,491 kWh |
$4,147 291 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,078 Cost: $1,200 |
$751 | 14,361 | $327 | 23 | - | - | - | - | - | - | - | - |
$751 14,361 kWh |
$327 23 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,879 Cost: - |
$4,708 | 89,683 | $171 | 12 | - | - | - | - | - | - | - | - |
$4,708 89,683 kWh |
$171 12 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.8143 RECYCLE CLEANING SOLVENT AND REUSE |
Savings: $2,412 Cost: $7,200 |
- | - | - | - | $451 | 425 | $(-1,784) | - | $3,745 | - | - | - |
- - kWh |
- - kW-months/year |
$451 425 gal |
$(-1,784) - $ |
$3,745 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.121 MAINTAIN CLEAN CONDITIONS BEFORE PAINTING |
Savings: $2,392 Cost: $5 |
- | - | - | - | - | - | - | - | - | - | $2,392 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - $ |
- - $ |
$2,392 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,385 Cost: $40,440 |
$22,125 | 398,592 | $8,456 | 593 | $451 | 425 | $(-1,784) | - | $3,745 | - | $2,392 | - | $22,125 398,592 kWh |
$8,456 593 kW-months/year |
$451 425 gal |
$(-1,784) - $ |
$3,745 - $ |
$2,392 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,581 Cost: $33,235 |
$22,125 | 398,592 | $8,456 | 593 | - | - | - | - | - | - | - | - | $22,125 398,592 kWh |
$8,456 593 kW-months/year |
- - gal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Other Liquid (haz) | Administrative Changes | Primary Raw Material | Primary Product |