Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 1998 |
Principal Product | Coolant Reservoirs |
NAICS | n/a |
SIC | 2789 - Bookbinding And Related Work |
Sales | $5,000,000-$10,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 5,500,000 Units |
Production Hrs. Annual | 6,336 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $94,300 | 2,760,258 | kWh | $0.03 |
Electricity Demand | $57,890 | 6,516 | kW-months/year | $8.88 |
Natural Gas | $7,220 | 1,715 | MMBtu | $4.21 |
TOTAL ENERGY COSTS | $166,268 | |||
RECOMMENDED SAVINGS* | $50,560 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $866 Cost: $1,540 |
$604 | 17,878 | $262 | 35 | - | - | - | - | - | - |
$604 17,878 kWh |
$262 35 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $727 Cost: $1,000 |
$679 | 13,482 | $48 | 24 | - | - | - | - | - | - |
$679 13,482 kWh |
$48 24 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $3,250 Cost: $100 |
- | - | - | - | - | - | $3,250 | 1,500 | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$3,250 1,500 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $1,804 Cost: $1,580 |
- | - | - | - | $1,804 | 585,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,804 585,000 Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,065 Cost: $9,154 |
- | - | - | - | - | - | - | - | $16,065 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$16,065 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.631 INSTALL AN UNINTERUPTABLE POWER SUPPLY |
Savings: $27,848 Cost: $10,800 |
- | - | - | - | - | - | - | - | $27,848 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$27,848 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,560 Cost: $24,174 |
$1,283 | 31,360 | $310 | 59 | $1,804 | 585,000 | $3,250 | 1,500 | $43,913 | - | $1,283 31,360 kWh |
$310 59 kW-months/year |
$1,804 585,000 Tgal |
$3,250 1,500 lb |
$43,913 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Primary Product |