Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2002
Principal Product Fabricated Assemblies
NAICS 332420 - Metal Tank (Heavy Gauge) Manufacturing
SIC 3443 - Fabricated Plate Work (boiler Shops)
Sales $10,000,000-$50,000,000
# of Employees 78
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 7,488
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $189,569 3,053,729 kWh $0.06
Electricity Demand $79,422 9,252 kW-months/year $8.58
Electricity Fees $9,924 - $ -
Natural Gas $227,448 34,803 MMBtu $6.54
TOTAL ENERGY COSTS $506,363
RECOMMENDED SAVINGS* $69,658 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $65,874
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.1114 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE Savings:
$28,900
Cost:
$10,000
- - - - $28,900 4,108 -
-
kWh
-
-
kW-months/year
$28,900
4,108
MMBtu
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$23,074
Cost:
$1,750
- - - - $23,074 3,588 -
-
kWh
-
-
kW-months/year
$23,074
3,588
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$13,900
Cost:
$1,275
$12,390 133,220 $1,510 183 - - $12,390
133,220
kWh
$1,510
183
kW-months/year
-
-
MMBtu
04: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$2,523
Cost:
$2,000
$2,523 27,130 - - - - $2,523
27,130
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,261
Cost:
$4,000
$895 9,620 $366 36 - - $895
9,620
kWh
$366
36
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$69,658
Cost:
$19,025
$15,808 169,970 $1,876 219 $51,974 7,696 $15,808
169,970
kWh
$1,876
219
kW-months/year
$51,974
7,696
MMBtu
TOTAL IMPLEMENTED Savings:
$65,874
Cost:
$13,025
$12,390 133,220 $1,510 183 $51,974 7,696 $12,390
133,220
kWh
$1,510
183
kW-months/year
$51,974
7,696
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas