Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2004 |
Principal Product | High purity chemicals |
NAICS | 325199 - All Other Basic Organic Chemical Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 115 |
Plant Area (Sq.Ft.) | 95,000 |
Annual Production | 1,600 Thousand Gallons |
Production Hrs. Annual | 6,120 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $116,130 | 2,350,178 | kWh | $0.05 |
Electricity Demand | $14,564 | 1,561 | kW-months/year | $9.33 |
Electricity Fees | $1,542 | - | $ | - |
Natural Gas | $168,958 | 26,417 | MMBtu | $6.40 |
TOTAL ENERGY COSTS | $301,194 | |||
RECOMMENDED SAVINGS* | $60,152 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,046 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $31,255 Cost: $30,000 |
$(-31,357) | (-885,043) | $(-1,082) | (-145) | - | - | $63,694 | - |
$(-31,357) (-885,043) kWh |
$(-1,082) (-145) kW-months/year |
- - MMBtu |
$63,694 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $9,650 Cost: $2,200 |
- | - | - | - | $9,650 | 1,508 | - | - |
- - kWh |
- - kW-months/year |
$9,650 1,508 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $6,907 Cost: - |
- | - | - | - | - | - | $6,907 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$6,907 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $3,584 Cost: $15,000 |
- | - | - | - | $3,584 | 560 | - | - |
- - kWh |
- - kW-months/year |
$3,584 560 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $3,267 Cost: $10,000 |
- | - | $3,267 | 341 | - | - | - | - |
- - kWh |
$3,267 341 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $3,010 Cost: $1,080 |
- | - | - | - | $3,010 | 470 | - | - |
- - kWh |
- - kW-months/year |
$3,010 470 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,479 Cost: $1,038 |
$1,608 | 44,928 | $871 | 93 | - | - | - | - |
$1,608 44,928 kWh |
$871 93 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $60,152 Cost: $59,318 |
$(-29,749) | (-840,115) | $3,056 | 289 | $16,244 | 2,538 | $70,601 | - | $(-29,749) (-840,115) kWh |
$3,056 289 kW-months/year |
$16,244 2,538 MMBtu |
$70,601 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,046 Cost: $4,318 |
$1,608 | 44,928 | $871 | 93 | $12,660 | 1,978 | $6,907 | - | $1,608 44,928 kWh |
$871 93 kW-months/year |
$12,660 1,978 MMBtu |
$6,907 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |