Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2004 |
Principal Product | Welded Steel Pressure Vessels |
NAICS | 332439 - Other Metal Container Manufacturing |
SIC | 3443 - Fabricated Plate Work (boiler Shops) |
Sales | $5,000,000-$10,000,000 |
# of Employees | 69 |
Plant Area (Sq.Ft.) | 160,932 |
Annual Production | 50,000 Pieces |
Production Hrs. Annual | 4,000 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $63,589 | 1,346,360 | kWh | $0.05 |
Electricity Demand | $29,934 | 7,014 | kW-months/year | $4.27 |
Electricity Fees | $5,618 | - | $ | - |
Natural Gas | $87,892 | 12,632 | MMBtu | $6.96 |
TOTAL ENERGY COSTS | $187,033 | |||
RECOMMENDED SAVINGS* | $33,214 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,125 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER |
Savings: $11,825 Cost: $4,500 |
- | - | - | - | $11,825 | 1,699 | - | - |
- - kWh |
- - kW-months/year |
$11,825 1,699 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,131 Cost: $7,512 |
$4,781 | 101,234 | $1,350 | 316 | - | - | - | - |
$4,781 101,234 kWh |
$1,350 316 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,042 Cost: $900 |
$3,971 | 84,294 | $1,071 | 253 | - | - | - | - |
$3,971 84,294 kWh |
$1,071 253 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $2,182 Cost: $1,000 |
- | - | - | - | $2,182 | 314 | - | - |
- - kWh |
- - kW-months/year |
$2,182 314 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,847 Cost: $2,000 |
$1,450 | 30,851 | $397 | 93 | - | - | - | - |
$1,450 30,851 kWh |
$397 93 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $1,400 Cost: $700 |
- | - | - | - | - | - | $1,400 | 7,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,400 7,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $1,312 Cost: $3,500 |
- | - | - | - | $1,312 | 432 | - | - |
- - kWh |
- - kW-months/year |
$1,312 432 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7244 REVISE SMOKE CLEANUP FROM OPERATIONS |
Savings: $1,614 Cost: $500 |
- | - | - | - | $1,614 | 232 | - | - |
- - kWh |
- - kW-months/year |
$1,614 232 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,195 Cost: $603 |
$1,195 | 25,428 | - | - | - | - | - | - |
$1,195 25,428 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES |
Savings: $666 Cost: $610 |
- | - | - | - | $666 | 76 | - | - |
- - kWh |
- - kW-months/year |
$666 76 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,214 Cost: $21,825 |
$11,397 | 241,807 | $2,818 | 662 | $17,599 | 2,753 | $1,400 | 7,000 | $11,397 241,807 kWh |
$2,818 662 kW-months/year |
$17,599 2,753 MMBtu |
$1,400 7,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,125 Cost: $16,022 |
$10,202 | 216,379 | $2,818 | 662 | $14,105 | 2,007 | - | - | $10,202 216,379 kWh |
$2,818 662 kW-months/year |
$14,105 2,007 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) |