Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2005
Principal Product Cardboard Boxes, Plastic Returnable Packaging
NAICS 322211 - Corrugated and Solid Fiber Box Manufacturing
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales $5,000,000-$10,000,000
# of Employees 46
Plant Area (Sq.Ft.) 130,000
Annual Production 92,000,000 Thousand Feet
Production Hrs. Annual 4,160
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $54,486 1,494,804 kWh $0.04
Electricity Demand $51,040 5,326 kW-months/year $9.58
Electricity Fees $2,396 - $ -
Natural Gas $66,636 8,885 MMBtu $7.50
TOTAL ENERGY COSTS $174,558
RECOMMENDED SAVINGS* $26,735 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $16,550
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$7,943
Cost:
$12,500
- - - - $7,943 1,059 -
-
kWh
-
-
kW-months/year
$7,943
1,059
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,268
Cost:
$11,077
$4,060 110,393 $3,208 335 - - $4,060
110,393
kWh
$3,208
335
kW-months/year
-
-
MMBtu
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$4,868
Cost:
$2,650
- - - - $4,868 649 -
-
kWh
-
-
kW-months/year
$4,868
649
MMBtu
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$2,753
Cost:
$6,230
- - - - $2,753 327 -
-
kWh
-
-
kW-months/year
$2,753
327
MMBtu
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$2,242
Cost:
-
- - $2,242 234 - - -
-
kWh
$2,242
234
kW-months/year
-
-
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,296
Cost:
$1,950
$578 15,849 $718 75 - - $578
15,849
kWh
$718
75
kW-months/year
-
-
MMBtu
07: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$365
Cost:
$720
- - - - $365 49 -
-
kWh
-
-
kW-months/year
$365
49
MMBtu
TOTAL RECOMMENDED Savings:
$26,735
Cost:
$35,127
$4,638 126,242 $6,168 644 $15,929 2,084 $4,638
126,242
kWh
$6,168
644
kW-months/year
$15,929
2,084
MMBtu
TOTAL IMPLEMENTED Savings:
$16,550
Cost:
$22,627
$4,638 126,242 $3,926 410 $7,986 1,025 $4,638
126,242
kWh
$3,926
410
kW-months/year
$7,986
1,025
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas