Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2011 |
Principal Product | Snack Foods |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | <$500,000 |
# of Employees | 184 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 6,240 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $218,328 | 4,512,024 | kWh | $0.05 |
Electricity Demand | $129,997 | 9,041 | kW-months/year | $14.38 |
Natural Gas | $354,225 | 60,903 | MMBtu | $5.82 |
TOTAL ENERGY COSTS | $702,550 | |||
RECOMMENDED SAVINGS* | $37,367 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,696 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS |
Savings: $17,794 Cost: $4,850 |
$11,323 | 234,000 | $6,471 | 450 | - | - | - | - |
$11,323 234,000 kWh |
$6,471 450 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,985 Cost: $5,032 |
$3,116 | 64,392 | $1,869 | 130 | - | - | - | - |
$3,116 64,392 kWh |
$1,869 130 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $2,946 Cost: $200 |
- | - | $1,999 | 139 | $947 | - | - | - |
- - kWh |
$1,999 139 kW-months/year |
$947 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $119 Cost: $600 |
$119 | 2,457 | - | - | - | - | - | - |
$119 2,457 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $82 Cost: $10 |
$82 | 1,700 | - | - | - | - | - | - |
$82 1,700 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,186 Cost: $1,200 |
- | - | - | - | - | - | $5,186 | 891 |
- - kWh |
- - kW-months/year |
- - $ |
$5,186 891 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,850 Cost: $1,100 |
- | - | - | - | - | - | $2,850 | 482 |
- - kWh |
- - kW-months/year |
- - $ |
$2,850 482 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $1,426 Cost: $3,926 |
- | - | - | - | - | - | $1,426 | 245 |
- - kWh |
- - kW-months/year |
- - $ |
$1,426 245 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,350 Cost: $783 |
- | - | - | - | - | - | $1,350 | 232 |
- - kWh |
- - kW-months/year |
- - $ |
$1,350 232 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $629 Cost: $220 |
- | - | - | - | - | - | $629 | 108 |
- - kWh |
- - kW-months/year |
- - $ |
$629 108 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $37,367 Cost: $17,921 |
$14,640 | 302,549 | $10,339 | 719 | $947 | - | $11,441 | 1,958 | $14,640 302,549 kWh |
$10,339 719 kW-months/year |
$947 - $ |
$11,441 1,958 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,696 Cost: $5,262 |
$3,198 | 66,092 | $1,869 | 130 | - | - | $629 | 108 | $3,198 66,092 kWh |
$1,869 130 kW-months/year |
- - $ |
$629 108 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |