Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2001
Principal Product Trailer manufacturer
NAICS n/a
SIC 3440 -
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 117,000
Annual Production 2,000 Pieces
Production Hrs. Annual 8,760
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $77,735 2,962,000 kWh $0.03
Electricity Demand $63,439 8,088 kW-months/year $7.84
Electricity Fees $1,009 - $ -
Natural Gas $41,292 7,588 MMBtu $5.44
TOTAL ENERGY COSTS $183,475
RECOMMENDED SAVINGS* $13,826 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,748
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$7,950
Cost:
$280
$5,416 190,045 $2,534 304 $5,416
190,045
kWh
$2,534
304
kW-months/year
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$798
Cost:
$932
- - $798 96 -
-
kWh
$798
96
kW-months/year
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,396
Cost:
$300
$1,614 63,356 $782 102 $1,614
63,356
kWh
$782
102
kW-months/year
04: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY Savings:
$2,070
Cost:
$10,000
$2,070 72,634 - - $2,070
72,634
kWh
-
-
kW-months/year
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$612
Cost:
$1,575
$418 29,308 $194 47 $418
29,308
kWh
$194
47
kW-months/year
TOTAL RECOMMENDED Savings:
$13,826
Cost:
$13,087
$9,518 355,343 $4,308 549 $9,518
355,343
kWh
$4,308
549
kW-months/year
TOTAL IMPLEMENTED Savings:
$8,748
Cost:
$1,212
$5,416 190,045 $3,332 400 $5,416
190,045
kWh
$3,332
400
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand