Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2002 |
Principal Product | Sporting Goods |
NAICS | n/a |
SIC | 3949 - Sporting And Athletic Goods, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 312 |
Plant Area (Sq.Ft.) | 110,000 |
Annual Production | 50,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $237,336 | 9,038,216 | kWh | $0.03 |
Electricity Demand | $166,709 | 21,719 | kW-months/year | $7.68 |
Electricity Fees | $49,276 | - | $ | - |
Natural Gas | $223,906 | 38,990 | MMBtu | $5.74 |
TOTAL ENERGY COSTS | $754,112 | |||
RECOMMENDED SAVINGS* | $76,526 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,793 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $11,006 Cost: $21,657 |
$7,807 | 259,053 | $3,199 | 364 | - | - | - | - | - | - |
$7,807 259,053 kWh |
$3,199 364 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,242 Cost: $2,173 |
$1,601 | 53,125 | $641 | 73 | - | - | - | - | - | - |
$1,601 53,125 kWh |
$641 73 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,257 Cost: $800 |
$897 | 29,752 | $360 | 41 | - | - | - | - | - | - |
$897 29,752 kWh |
$360 41 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,089 Cost: $489 |
$777 | 25,833 | $312 | 35 | - | - | - | - | - | - |
$777 25,833 kWh |
$312 35 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,441 Cost: $2,664 |
$1,503 | 49,886 | $938 | 107 | - | - | - | - | - | - |
$1,503 49,886 kWh |
$938 107 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2514 COVER OPEN TANKS |
Savings: $739 Cost: $100 |
- | - | - | - | $739 | 158 | - | - | - | - |
- - kWh |
- - kW-months/year |
$739 158 MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.8225 REPLACE HEXAVALENT CHROMIUM SOLUTIONS WITH TRIVALENT SOLUTIONS |
Savings: $716 Cost: - |
- | - | - | - | - | - | - | - | $716 | 716 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$716 716 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $6,853 Cost: $1,570 |
- | - | - | - | - | - | $6,853 | 2,914,635 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$6,853 2,914,635 Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $50,183 Cost: $98,800 |
- | - | - | - | - | - | $50,183 | 20,404,037 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$50,183 20,404,037 Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,526 Cost: $128,253 |
$12,585 | 417,649 | $5,450 | 620 | $739 | 158 | $57,036 | 23,318,672 | $716 | 716 | $12,585 417,649 kWh |
$5,450 620 kW-months/year |
$739 158 MMBtu |
$57,036 23,318,672 Tgal |
$716 716 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,793 Cost: $25,610 |
$10,984 | 364,524 | $4,809 | 547 | - | - | - | - | - | - | $10,984 364,524 kWh |
$4,809 547 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) |