IAC logo
IAC Assessment: UU0020
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UU0020
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2002
Principal Product Sporting Goods
NAICS n/a
SIC 3949 - Sporting And Athletic Goods, Nec
Sales $10,000,000-$50,000,000
# of Employees 312
Plant Area (Sq.Ft.) 110,000
Annual Production 50,000,000 Pieces
Production Hrs. Annual 8,760
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $237,336 9,038,216 kWh $0.03
Electricity Demand $166,709 21,719 kW-months/year $7.68
Electricity Fees $49,276 - $ -
Natural Gas $223,906 38,990 MMBtu $5.74
TOTAL ENERGY COSTS $754,112
RECOMMENDED SAVINGS* $76,526 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,793
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz)
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$11,006
Cost:
$21,657
$7,807 259,053 $3,199 364 - - - - - - $7,807
259,053
kWh
$3,199
364
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,242
Cost:
$2,173
$1,601 53,125 $641 73 - - - - - - $1,601
53,125
kWh
$641
73
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
03: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$1,257
Cost:
$800
$897 29,752 $360 41 - - - - - - $897
29,752
kWh
$360
41
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,089
Cost:
$489
$777 25,833 $312 35 - - - - - - $777
25,833
kWh
$312
35
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,441
Cost:
$2,664
$1,503 49,886 $938 107 - - - - - - $1,503
49,886
kWh
$938
107
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
06: 2.2514 COVER OPEN TANKS Savings:
$739
Cost:
$100
- - - - $739 158 - - - - -
-
kWh
-
-
kW-months/year
$739
158
MMBtu
-
-
Tgal
-
-
lb
07: 3.8225 REPLACE HEXAVALENT CHROMIUM SOLUTIONS WITH TRIVALENT SOLUTIONS Savings:
$716
Cost:
-
- - - - - - - - $716 716 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$716
716
lb
08: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE Savings:
$6,853
Cost:
$1,570
- - - - - - $6,853 2,914,635 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$6,853
2,914,635
Tgal
-
-
lb
09: 3.4113 TREAT AND REUSE RINSE WATERS Savings:
$50,183
Cost:
$98,800
- - - - - - $50,183 20,404,037 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$50,183
20,404,037
Tgal
-
-
lb
TOTAL RECOMMENDED Savings:
$76,526
Cost:
$128,253
$12,585 417,649 $5,450 620 $739 158 $57,036 23,318,672 $716 716 $12,585
417,649
kWh
$5,450
620
kW-months/year
$739
158
MMBtu
$57,036
23,318,672
Tgal
$716
716
lb
TOTAL IMPLEMENTED Savings:
$15,793
Cost:
$25,610
$10,984 364,524 $4,809 547 - - - - - - $10,984
364,524
kWh
$4,809
547
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
lb
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ lb
Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Water Disposal Solid Waste (non-haz)