Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2018 |
Principal Product | Limestone |
NAICS | 327410 - Lime Manufacturing |
SIC | 3281 - Cut Stone And Stone Products |
Sales | $50,000,000-$100,000,000 |
# of Employees | 72 |
Plant Area (Sq.Ft.) | 12,000 |
Annual Production | 698,000 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,477,529 | 45,444,000 | kWh | $0.03 |
Electricity Demand | $502,320 | 46,748 | kW-months/year | $10.75 |
Electricity Fees | $6,864 | - | $ | - |
Coal | $4,300,000 | 2,600,000 | MMBtu | $1.65 |
TOTAL ENERGY COSTS | $6,286,712 | |||
RECOMMENDED SAVINGS* | $734,281 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,616 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Coal | Electricity Usage | Electricity Demand | Electricity Fees | Coal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $473,255 Cost: $175,000 |
$80,015 | 2,330,000 | $37,552 | 3,240 | $7,328 | - | $348,360 | 210,740 |
$80,015 2,330,000 kWh |
$37,552 3,240 kW-months/year |
$7,328 - $ |
$348,360 210,740 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $206,416 Cost: $1,600 |
- | - | - | - | $206,416 | - | - | - |
- - kWh |
- - kW-months/year |
$206,416 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $30,169 Cost: $97,680 |
- | - | - | - | - | - | $30,169 | 18,252 |
- - kWh |
- - kW-months/year |
- - $ |
$30,169 18,252 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $15,825 Cost: - |
$10,189 | 297,046 | $4,716 | 407 | $921 | - | - | - |
$10,189 297,046 kWh |
$4,716 407 kW-months/year |
$921 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,767 Cost: $5,679 |
$3,008 | 87,684 | $2,309 | 199 | $451 | - | - | - |
$3,008 87,684 kWh |
$2,309 199 kW-months/year |
$451 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,849 Cost: $1,155 |
$2,849 | 83,065 | - | - | - | - | - | - |
$2,849 83,065 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $734,281 Cost: $281,114 |
$96,060 | 2,797,796 | $44,577 | 3,846 | $215,115 | - | $378,529 | 228,992 | $96,060 2,797,796 kWh |
$44,577 3,846 kW-months/year |
$215,115 - $ |
$378,529 228,992 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,616 Cost: $6,834 |
$5,857 | 170,750 | $2,309 | 199 | $451 | - | - | - | $5,857 170,750 kWh |
$2,309 199 kW-months/year |
$451 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Coal | Electricity Usage | Electricity Demand | Electricity Fees | Coal |