Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2019 |
Principal Product | Molded Plastic Parts |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 95 |
Plant Area (Sq.Ft.) | 61,900 |
Annual Production | 6,100 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $139,171 | 3,812,639 | kWh | $0.04 |
Electricity Demand | $107,676 | 6,632 | kW-months/year | $16.24 |
Electricity Fees | $63,345 | - | $ | - |
Natural Gas | $3,853 | 507 | MMBtu | $7.60 |
TOTAL ENERGY COSTS | $314,045 | |||
RECOMMENDED SAVINGS* | $73,867 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $36,471 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $33,354 Cost: $66,174 |
$20,507 | 561,817 | $12,847 | 791 | - | - | - | - |
$20,507 561,817 kWh |
$12,847 791 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $12,915 Cost: $9,000 |
- | - | - | - | - | - | $12,915 | - |
- - kWh |
- - kW-months/year |
- - $ |
$12,915 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $10,938 Cost: $2,000 |
- | - | - | - | $10,938 | - | - | - |
- - kWh |
- - kW-months/year |
$10,938 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,593 Cost: $32,661 |
$5,977 | 163,737 | $3,616 | 223 | - | - | - | - |
$5,977 163,737 kWh |
$3,616 223 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $2,562 Cost: $4,000 |
- | - | $2,562 | 158 | - | - | - | - |
- - kWh |
$2,562 158 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $1,817 Cost: $3,415 |
$811 | 22,220 | $1,005 | 62 | - | - | - | - |
$811 22,220 kWh |
$1,005 62 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,480 Cost: $3,445 |
$785 | 21,514 | $695 | 43 | - | - | - | - |
$785 21,514 kWh |
$695 43 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,208 Cost: $231 |
$749 | 20,519 | $459 | 28 | - | - | - | - |
$749 20,519 kWh |
$459 28 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $73,867 Cost: $120,926 |
$28,830 | 789,807 | $21,184 | 1,305 | $10,938 | - | $12,915 | - | $28,830 789,807 kWh |
$21,184 1,305 kW-months/year |
$10,938 - $ |
$12,915 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $36,471 Cost: $47,307 |
$7,537 | 206,476 | $5,080 | 313 | $10,938 | - | $12,915 | - | $7,537 206,476 kWh |
$5,080 313 kW-months/year |
$10,938 - $ |
$12,915 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material |