Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2021 |
Principal Product | Refined Metal Ingots |
NAICS | 331410 - Nonferrous Metal (except Aluminum) Smelting and Refining |
SIC | 3339 - Primary Nonferrous Metals, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 66,700 |
Annual Production | 550 Tons |
Production Hrs. Annual | 8,400 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $482,402 | 12,835,200 | kWh | $0.04 |
Electricity Demand | $515,115 | 28,428 | kW-months/year | $18.12 |
Electricity Fees | $46,318 | - | $ | - |
Natural Gas | $163,550 | 37,340 | MMBtu | $4.38 |
TOTAL ENERGY COSTS | $1,217,385 | |||
RECOMMENDED SAVINGS* | $173,012 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $72,940 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $57,706 Cost: $128,174 |
$34,179 | 909,510 | $23,527 | 1,298 | - | - | - | - |
$34,179 909,510 kWh |
$23,527 1,298 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $36,240 Cost: $6,760 |
- | - | $36,240 | 2,000 | - | - | - | - |
- - kWh |
$36,240 2,000 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $32,792 Cost: $101,000 |
- | - | - | - | - | - | $32,792 | 7,487 |
- - kWh |
- - kW-months/year |
- - $ |
$32,792 7,487 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $12,515 Cost: $5,046 |
$7,413 | 197,114 | $5,102 | 282 | - | - | - | - |
$7,413 197,114 kWh |
$5,102 282 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $10,455 Cost: $14,250 |
- | - | - | - | $10,455 | - | - | - |
- - kWh |
- - kW-months/year |
$10,455 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,132 Cost: $22,614 |
$8,132 | 216,389 | - | - | - | - | - | - |
$8,132 216,389 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,105 Cost: $11,650 |
$4,799 | 127,712 | $3,305 | 182 | - | - | - | - |
$4,799 127,712 kWh |
$3,305 182 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7314 REDUCE VENTILATION AIR |
Savings: $4,129 Cost: $4,000 |
$330 | 8,780 | - | - | - | - | $3,799 | 867 |
$330 8,780 kWh |
- - kW-months/year |
- - $ |
$3,799 867 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $1,497 Cost: $100 |
$113 | 3,000 | - | - | - | - | $1,384 | 316 |
$113 3,000 kWh |
- - kW-months/year |
- - $ |
$1,384 316 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,441 Cost: $1,625 |
$1,441 | 38,342 | - | - | - | - | - | - |
$1,441 38,342 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $173,012 Cost: $295,219 |
$56,407 | 1,500,847 | $68,175 | 3,762 | $10,455 | - | $37,975 | 8,670 | $56,407 1,500,847 kWh |
$68,175 3,762 kW-months/year |
$10,455 - $ |
$37,975 8,670 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $72,940 Cost: $41,806 |
$12,655 | 336,606 | $44,648 | 2,464 | $10,455 | - | $5,183 | 1,183 | $12,655 336,606 kWh |
$44,648 2,464 kW-months/year |
$10,455 - $ |
$5,183 1,183 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |