Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2023 |
Principal Product | Power Generators |
NAICS | 335312 - Motor and Generator Manufacturing |
SIC | 3621 - Motors And Generators |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 600 Units |
Production Hrs. Annual | 2,100 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,808 | 1,206,000 | kWh | $0.04 |
Electricity Demand | $66,169 | 4,048 | kW-months/year | $16.35 |
Electricity Fees | $9,746 | - | $ | - |
Natural Gas | $69,339 | 6,871 | MMBtu | $10.09 |
TOTAL ENERGY COSTS | $189,063 | |||
RECOMMENDED SAVINGS* | $29,892 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,000 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $8,860 Cost: $4,445 |
- | - | - | - | $8,860 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,860 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $7,404 Cost: $5,700 |
$3,089 | 85,800 | $4,315 | 264 | - | - | - | - | - | - |
$3,089 85,800 kWh |
$4,315 264 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,223 Cost: $53,198 |
$2,414 | 67,056 | $2,809 | 172 | - | - | - | - | - | - |
$2,414 67,056 kWh |
$2,809 172 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.811 DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS |
Savings: $3,088 Cost: $3,300 |
- | - | - | - | - | - | - | - | $3,088 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$3,088 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $2,944 Cost: $78,979 |
$2,699 | 74,971 | $245 | 15 | - | - | - | - | - | - |
$2,699 74,971 kWh |
$245 15 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $1,861 Cost: $721 |
$187 | 5,194 | - | - | - | - | $1,674 | 166 | - | - |
$187 5,194 kWh |
- - kW-months/year |
- - $ |
$1,674 166 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $512 Cost: $161 |
$315 | 8,760 | $196 | 12 | - | - | - | - | - | - |
$315 8,760 kWh |
$196 12 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,892 Cost: $146,504 |
$8,704 | 241,781 | $7,566 | 463 | $8,860 | - | $1,674 | 166 | $3,088 | - | $8,704 241,781 kWh |
$7,566 463 kW-months/year |
$8,860 - $ |
$1,674 166 MMBtu |
$3,088 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,000 Cost: $59,780 |
$6,005 | 166,810 | $7,320 | 448 | - | - | $1,674 | 166 | - | - | $6,005 166,810 kWh |
$7,320 448 kW-months/year |
- - $ |
$1,674 166 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | One-time Revenue or Avoided Cost |