Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2024
Principal Product Socks, Belts, Wallets
NAICS 315990 - Apparel Accessories and Other Apparel Manufacturing
SIC 2389 - Apparel And Accessories, Nec
Sales $5,000,000-$10,000,000
# of Employees 27
Plant Area (Sq.Ft.) 60,000
Annual Production 92,900 Units
Production Hrs. Annual 7,056
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $26,684 743,800 kWh $0.04
Electricity Demand $44,880 2,759 kW-months/year $16.27
Electricity Fees $16,512 - $ -
Natural Gas $13,133 1,075 MMBtu $12.22
TOTAL ENERGY COSTS $101,209
RECOMMENDED SAVINGS* $21,529 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$439
Cost:
$900
- - $439 27 - - -
-
kWh
$439
27
kW-months/year
-
-
$
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$3,514
Cost:
$9,000
- - - - $3,514 - -
-
kWh
-
-
kW-months/year
$3,514
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,628
Cost:
$3,000
$1,052 29,300 $576 35 - - $1,052
29,300
kWh
$576
35
kW-months/year
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$520
Cost:
$123
$325 8,900 $195 12 - - $325
8,900
kWh
$195
12
kW-months/year
-
-
$
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,731
Cost:
$338
$1,731 48,090 - - - - $1,731
48,090
kWh
-
-
kW-months/year
-
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$8,970
Cost:
$42,406
$6,172 172,022 $2,798 172 - - $6,172
172,022
kWh
$2,798
172
kW-months/year
-
-
$
07: 3.1194 USE AUTOMATIC FLOW CONTROL Savings:
$4,727
Cost:
$4,633
$2,189 60,803 $2,538 156 - - $2,189
60,803
kWh
$2,538
156
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$21,529
Cost:
$60,400
$11,469 319,115 $6,546 402 $3,514 - $11,469
319,115
kWh
$6,546
402
kW-months/year
$3,514
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees