IAC logo
IAC Assessment: UU0262
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UU0262
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2025
Principal Product Ceramic Substrates
NAICS 334419 - Other Electronic Component Manufacturing
SIC 3679 - Electronic Components, Nec
Sales $5,000,000-$10,000,000
# of Employees 50
Plant Area (Sq.Ft.) 39,229
Annual Production 6,000,000 Units
Production Hrs. Annual 5,880
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $31,625 718,744 kWh $0.04
Electricity Demand $38,896 2,307 kW-months/year $16.86
Electricity Fees $22,088 - $ -
Natural Gas $213,142 26,721 MMBtu $7.98
Other Gas $46,454 3,718 MMBtu $12.49
TOTAL ENERGY COSTS $352,205
RECOMMENDED SAVINGS* $73,240 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes
$ kWh $ kW-months/year $ $ $ MMBtu $ $
01: 2.2693 USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION Savings:
$12,361
Cost:
$217,800
$7,086 157,471 $6,130 364 - - - - $(-855) - $7,086
157,471
kWh
$6,130
364
kW-months/year
-
-
$
-
-
MMBtu
$(-855)
-
$
02: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR Savings:
$14,276
Cost:
$180,000
$12,800 290,000 $6,676 396 - - - - $(-5,200) - $12,800
290,000
kWh
$6,676
396
kW-months/year
-
-
$
-
-
MMBtu
$(-5,200)
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$24,314
Cost:
$29,878
- - - - - - $24,314 3,048 - - -
-
kWh
-
-
kW-months/year
-
-
$
$24,314
3,048
MMBtu
-
-
$
04: 2.7251 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF Savings:
$13,561
Cost:
$178,488
$8,097 184,032 $6,464 383 - - - - $(-1,000) - $8,097
184,032
kWh
$6,464
383
kW-months/year
-
-
$
-
-
MMBtu
$(-1,000)
-
$
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$762
Cost:
$2,640
$301 6,694 $461 27 - - - - - - $301
6,694
kWh
$461
27
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
06: 2.6242 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION Savings:
$720
Cost:
$1,680
$394 8,753 $326 19 - - - - - - $394
8,753
kWh
$326
19
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,117
Cost:
$834
$1,219 27,706 $898 53 - - - - - - $1,219
27,706
kWh
$898
53
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
08: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$5,129
Cost:
$12,300
- - - - $5,129 - - - - - -
-
kWh
-
-
kW-months/year
$5,129
-
$
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$73,240
Cost:
$623,620
$29,897 674,656 $20,955 1,243 $5,129 - $24,314 3,048 $(-7,055) - $29,897
674,656
kWh
$20,955
1,243
kW-months/year
$5,129
-
$
$24,314
3,048
MMBtu
$(-7,055)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes