Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2025
Principal Product Machined parts
NAICS 332510 - Hardware Manufacturing
SIC 3499 - Fabricated Metal Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 60
Plant Area (Sq.Ft.) 42,000
Annual Production 1,500,000 Units
Production Hrs. Annual 7,488
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $61,096 1,697,100 kWh $0.04
Electricity Demand $58,644 3,600 kW-months/year $16.29
Electricity Fees $34,291 - $ -
Natural Gas $39,870 3,962 MMBtu $10.06
TOTAL ENERGY COSTS $193,901
RECOMMENDED SAVINGS* $34,668 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Water Usage Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Natural Gas Water Usage Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ Tgal $ $
01: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$3,730
Cost:
$6,750
- - $3,730 229 - - - - - - - - -
-
kWh
$3,730
229
kW-months/year
-
-
$
-
-
MMBtu
-
-
Tgal
-
-
$
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$2,200
Cost:
$6,000
- - - - $2,200 - - - - - - - -
-
kWh
-
-
kW-months/year
$2,200
-
$
-
-
MMBtu
-
-
Tgal
-
-
$
03: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$6,322
Cost:
$119,100
$4,792 133,115 $2,948 181 - - - - $(-1,419) (-710) - - $4,792
133,115
kWh
$2,948
181
kW-months/year
-
-
$
-
-
MMBtu
$(-1,419)
(-710)
Tgal
-
-
$
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$2,650
Cost:
$9,727
- - - - - - $2,650 265 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$2,650
265
MMBtu
-
-
Tgal
-
-
$
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,456
Cost:
$3,600
$906 25,161 $551 34 - - - - - - - - $906
25,161
kWh
$551
34
kW-months/year
-
-
$
-
-
MMBtu
-
-
Tgal
-
-
$
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$3,113
Cost:
$29,674
$1,924 53,436 $1,189 73 - - - - - - - - $1,924
53,436
kWh
$1,189
73
kW-months/year
-
-
$
-
-
MMBtu
-
-
Tgal
-
-
$
07: 3.1194 USE AUTOMATIC FLOW CONTROL Savings:
$2,903
Cost:
$6,218
$1,535 42,638 $1,368 84 - - - - - - - - $1,535
42,638
kWh
$1,368
84
kW-months/year
-
-
$
-
-
MMBtu
-
-
Tgal
-
-
$
08: 3.4145 USE MAGNETIC TECHNOLOGY TO TREAT WATER Savings:
$12,294
Cost:
$19,900
$(-530) (-14,717) $(-328) (-20) - - $24,144 2,400 - - $(-10,992) - $(-530)
(-14,717)
kWh
$(-328)
(-20)
kW-months/year
-
-
$
$24,144
2,400
MMBtu
-
-
Tgal
$(-10,992)
-
$
TOTAL RECOMMENDED Savings:
$34,668
Cost:
$200,969
$8,627 239,633 $9,458 581 $2,200 - $26,794 2,665 $(-1,419) (-710) $(-10,992) - $8,627
239,633
kWh
$9,458
581
kW-months/year
$2,200
-
$
$26,794
2,665
MMBtu
$(-1,419)
(-710)
Tgal
$(-10,992)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ Tgal $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas Water Usage Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Natural Gas Water Usage Ancillary Material Cost