Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Washington |
---|---|
Assessment Year | 2008 |
Principal Product | Fiber Reinforced Composites |
NAICS | 339999 - All Other Miscellaneous Manufacturing |
SIC | 3999 - Manufacturing Industries, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 82,000 |
Annual Production | 50,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | WA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $76,444 | 2,335,680 | kWh | $0.03 |
Electricity Demand | $35,580 | 6,000 | kW-months/year | $5.93 |
Natural Gas | $287,214 | 27,129 | MMBtu | $10.59 |
TOTAL ENERGY COSTS | $399,238 | |||
RECOMMENDED SAVINGS* | $142,437 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,231 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.5195 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS |
Savings: $115,054 Cost: $172,581 |
$7,314 | 223,454 | $1,816 | 35 | $105,924 | 10,920 | - | - | - | - |
$7,314 223,454 kWh |
$1,816 35 kW-months/year |
$105,924 10,920 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $17,000 Cost: $24,547 |
$12,760 | 389,869 | $4,240 | 740 | - | - | - | - | - | - |
$12,760 389,869 kWh |
$4,240 740 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $8,002 Cost: $34,238 |
- | - | - | - | - | - | $3,338 | 67,500 | $4,664 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,338 67,500 lb |
$4,664 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,828 Cost: $450 |
$1,828 | 55,861 | - | - | - | - | - | - | - | - |
$1,828 55,861 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $403 Cost: $145 |
$346 | 6,169 | $57 | 1 | - | - | - | - | - | - |
$346 6,169 kWh |
$57 1 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $150 Cost: $809 |
$150 | 4,587 | - | - | - | - | - | - | - | - |
$150 4,587 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $142,437 Cost: $232,770 |
$22,398 | 679,940 | $6,113 | 776 | $105,924 | 10,920 | $3,338 | 67,500 | $4,664 | - | $22,398 679,940 kWh |
$6,113 776 kW-months/year |
$105,924 10,920 MMBtu |
$3,338 67,500 lb |
$4,664 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,231 Cost: $595 |
$2,174 | 62,030 | $57 | 1 | - | - | - | - | - | - | $2,174 62,030 kWh |
$57 1 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Primary Raw Material |