IAC logo
IAC Assessment: UW0053
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UW0053
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Washington
Assessment Year 2011
Principal Product Newsprint
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2741 - Miscellaneous Publishing
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 60,000
Annual Production 500,000 Pieces
Production Hrs. Annual 2,210
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $146,234 1,124,800 kWh $0.13
Electricity Demand $13,562 4,513 kW-months/year $3.01
TOTAL ENERGY COSTS $159,796
RECOMMENDED SAVINGS* $62,695 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $54,271
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$29,663
Cost:
$160,551
$27,308 210,065 $2,355 765 $27,308
210,065
kWh
$2,355
765
kW-months/year
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$13,673
Cost:
$11,000
$12,708 97,756 $965 313 $12,708
97,756
kWh
$965
313
kW-months/year
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$10,936
Cost:
$1,900
$10,592 81,509 $344 111 $10,592
81,509
kWh
$344
111
kW-months/year
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,830
Cost:
$21,939
$4,038 31,059 $792 264 $4,038
31,059
kWh
$792
264
kW-months/year
05: 2.7446 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS Savings:
$3,594
Cost:
$3,150
$3,594 27,648 - - $3,594
27,648
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$62,695
Cost:
$198,540
$58,240 448,037 $4,455 1,453 $58,240
448,037
kWh
$4,455
1,453
kW-months/year
TOTAL IMPLEMENTED Savings:
$54,271
Cost:
$173,451
$50,608 389,330 $3,663 1,189 $50,608
389,330
kWh
$3,663
1,189
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand