IAC logo
IAC Assessment: WI0035
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0035
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1988
Principal Product BATHROOM SCALES
NAICS n/a
SIC 3596 - Scales And Balances, Exc. Laboratory
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 0
Annual Production 2,000,000 Pieces
Production Hrs. Annual 4,250
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $179,044 1,944,607 kWh $0.09
Natural Gas $81,519 24,289 MMBtu $3.36
TOTAL ENERGY COSTS $260,563
RECOMMENDED SAVINGS* $23,946 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$3,262
Cost:
-
$3,262 35,463 - - - - $3,262
35,463
kWh
-
-
MMBtu
-
-
$
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$850
Cost:
-
$850 9,379 - - - - $850
9,379
kWh
-
-
MMBtu
-
-
$
03: 2.6232 INSTALL SET-BACK TIMERS Savings:
$2,537
Cost:
$331
$2,537 27,550 - - - - $2,537
27,550
kWh
-
-
MMBtu
-
-
$
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$3,816
Cost:
$5,000
$3,816 - - - - - $3,816
-
kWh
-
-
MMBtu
-
-
$
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$3,192
Cost:
$1,500
$3,780 41,032 $(-588) (-175) - - $3,780
41,032
kWh
$(-588)
(-175)
MMBtu
-
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$930
Cost:
$1,400
- - $930 277 - - -
-
kWh
$930
277
MMBtu
-
-
$
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$2,208
Cost:
$250
- - $2,358 702 $(-150) - -
-
kWh
$2,358
702
MMBtu
$(-150)
-
$
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$80
Cost:
$250
- - $230 68 $(-150) - -
-
kWh
$230
68
MMBtu
$(-150)
-
$
09: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,071
Cost:
$10,000
- - $7,071 2,104 - - -
-
kWh
$7,071
2,104
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$23,946
Cost:
$18,731
$14,245 113,424 $10,001 2,976 $(-300) - $14,245
113,424
kWh
$10,001
2,976
MMBtu
$(-300)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes