IAC logo
IAC Assessment: WI0059
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0059
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1989
Principal Product VINYL FLOORING
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 205
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 6,600
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $264,863 5,822,978 kWh $0.05
Natural Gas $179,743 38,364 MMBtu $4.69
TOTAL ENERGY COSTS $444,606
RECOMMENDED SAVINGS* $41,509 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $22,190
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$12,658
Cost:
-
$12,658 278,429 - - $12,658
278,429
kWh
-
-
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$8,983
Cost:
$800
- - $8,983 1,915 -
-
kWh
$8,983
1,915
MMBtu
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$7,916
Cost:
$5,000
- - $7,916 1,688 -
-
kWh
$7,916
1,688
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,025
Cost:
$3,000
- - $5,025 1,071 -
-
kWh
$5,025
1,071
MMBtu
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$2,400
Cost:
$3,750
$2,400 - - - $2,400
-
kWh
-
-
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,517
Cost:
$2,000
$1,517 33,411 - - $1,517
33,411
kWh
-
-
MMBtu
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,374
Cost:
-
$1,374 30,188 - - $1,374
30,188
kWh
-
-
MMBtu
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$929
Cost:
$1,000
- - $929 198 -
-
kWh
$929
198
MMBtu
09: 2.6232 INSTALL SET-BACK TIMERS Savings:
$449
Cost:
$400
$449 9,965 - - $449
9,965
kWh
-
-
MMBtu
10: 2.2511 INSULATE BARE EQUIPMENT Savings:
$258
Cost:
$175
$305 6,741 $(-47) (-10) $305
6,741
kWh
$(-47)
(-10)
MMBtu
TOTAL RECOMMENDED Savings:
$41,509
Cost:
$16,125
$18,703 358,734 $22,806 4,862 $18,703
358,734
kWh
$22,806
4,862
MMBtu
TOTAL IMPLEMENTED Savings:
$22,190
Cost:
$11,550
$5,291 63,599 $16,899 3,603 $5,291
63,599
kWh
$16,899
3,603
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas