IAC logo
IAC Assessment: WI0060
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0060
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1989
Principal Product TRUCK & VAN BODIES
NAICS n/a
SIC 3731 - Ship Building And Repairing
Sales $10,000,000-$50,000,000
# of Employees 96
Plant Area (Sq.Ft.) 0
Annual Production 2,400 Pieces
Production Hrs. Annual 4,027
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $48,410 766,413 kWh $0.06
Natural Gas $35,312 6,933 MMBtu $5.09
TOTAL ENERGY COSTS $83,722
RECOMMENDED SAVINGS* $14,550 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $9,758
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$6,260
Cost:
$1,800
- - $6,260 1,230 -
-
kWh
$6,260
1,230
MMBtu
02: 2.2532 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD Savings:
$3,041
Cost:
$231
$703 11,137 $2,338 459 $703
11,137
kWh
$2,338
459
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,289
Cost:
$1,193
$1,289 20,223 - - $1,289
20,223
kWh
-
-
MMBtu
04: 2.1123 INSTALL AUTOMATIC STACK DAMPER Savings:
$2,209
Cost:
$1,200
- - $2,209 434 -
-
kWh
$2,209
434
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$1,751
Cost:
$4,000
- - $1,751 344 -
-
kWh
$1,751
344
MMBtu
TOTAL RECOMMENDED Savings:
$14,550
Cost:
$8,424
$1,992 31,360 $12,558 2,467 $1,992
31,360
kWh
$12,558
2,467
MMBtu
TOTAL IMPLEMENTED Savings:
$9,758
Cost:
$4,193
$1,289 20,223 $8,469 1,664 $1,289
20,223
kWh
$8,469
1,664
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas