IAC logo
IAC Assessment: WI0094
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0094
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1990
Principal Product STEEL PIPES
NAICS n/a
SIC 3317 - Steel Pipe And Tubes
Sales $10,000,000-$50,000,000
# of Employees 115
Plant Area (Sq.Ft.) 0
Annual Production 30,000 Tons
Production Hrs. Annual 2,125
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $141,572 1,289,566 kWh $0.11
Natural Gas $48,722 9,906 MMBtu $4.92
TOTAL ENERGY COSTS $190,294
RECOMMENDED SAVINGS* $11,847 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,983
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,067
Cost:
$3,222
$3,067 28,136 - - $3,067
28,136
kWh
-
-
MMBtu
02: 2.7494 INSTALL STORM WINDOWS AND DOORS Savings:
$3,800
Cost:
$8,566
- - $3,800 772 -
-
kWh
$3,800
772
MMBtu
03: 2.6232 INSTALL SET-BACK TIMERS Savings:
$2,284
Cost:
$1,000
$2,284 20,809 - - $2,284
20,809
kWh
-
-
MMBtu
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$975
Cost:
$500
- - $975 198 -
-
kWh
$975
198
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$505
Cost:
-
$505 4,689 - - $505
4,689
kWh
-
-
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$489
Cost:
$1,500
- - $489 99 -
-
kWh
$489
99
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$219
Cost:
$800
$219 2,052 - - $219
2,052
kWh
-
-
MMBtu
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$508
Cost:
$700
- - $508 103 -
-
kWh
$508
103
MMBtu
TOTAL RECOMMENDED Savings:
$11,847
Cost:
$16,288
$6,075 55,686 $5,772 1,172 $6,075
55,686
kWh
$5,772
1,172
MMBtu
TOTAL IMPLEMENTED Savings:
$3,983
Cost:
$2,300
$3,008 27,550 $975 198 $3,008
27,550
kWh
$975
198
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas