IAC logo
IAC Assessment: WI0102
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0102
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1990
Principal Product PACKAGING FOR CANS
NAICS n/a
SIC 2657 - Folding Paperboard Boxes
Sales $10,000,000-$50,000,000
# of Employees 85
Plant Area (Sq.Ft.) 0
Annual Production 278,000 Pieces
Production Hrs. Annual 8,400
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $146,323 3,776,964 kWh $0.04
Natural Gas $97,493 31,414 MMBtu $3.10
TOTAL ENERGY COSTS $243,816
RECOMMENDED SAVINGS* $9,605 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,353
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$2,402
Cost:
$2,500
- - $2,402 775 -
-
kWh
$2,402
775
MMBtu
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,684
Cost:
$900
- - $1,684 543 -
-
kWh
$1,684
543
MMBtu
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,216
Cost:
$500
- - $1,216 393 -
-
kWh
$1,216
393
MMBtu
04: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$56
Cost:
$66
- - $56 18 -
-
kWh
$56
18
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$362
Cost:
$759
$362 9,379 - - $362
9,379
kWh
-
-
MMBtu
06: 2.6232 INSTALL SET-BACK TIMERS Savings:
$439
Cost:
$200
$439 11,430 - - $439
11,430
kWh
-
-
MMBtu
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$999
Cost:
$705
$999 25,791 - - $999
25,791
kWh
-
-
MMBtu
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$176
Cost:
-
$176 4,396 - - $176
4,396
kWh
-
-
MMBtu
09: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$990
Cost:
$1,400
- - $990 320 -
-
kWh
$990
320
MMBtu
10: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$900
Cost:
$2,000
$900 23,154 - - $900
23,154
kWh
-
-
MMBtu
11: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$381
Cost:
$350
- - $381 123 -
-
kWh
$381
123
MMBtu
TOTAL RECOMMENDED Savings:
$9,605
Cost:
$9,380
$2,876 74,150 $6,729 2,172 $2,876
74,150
kWh
$6,729
2,172
MMBtu
TOTAL IMPLEMENTED Savings:
$7,353
Cost:
$5,221
$1,614 41,617 $5,739 1,852 $1,614
41,617
kWh
$5,739
1,852
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas