Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1996 |
Principal Product | Industrial Brushes |
NAICS | n/a |
SIC | 3991 - Brooms And Brushes |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 8,000,000 Pieces |
Production Hrs. Annual | 4,250 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $25,021 | 401,817 | kWh | $0.06 |
Electricity Demand | $11,313 | 1,293 | kW-months/year | $8.75 |
Electricity Fees | $234 | - | $ | - |
Natural Gas | $15,481 | 3,439 | MMBtu | $4.50 |
TOTAL ENERGY COSTS | $52,574 | |||
RECOMMENDED SAVINGS* | $9,833 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,653 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,808 Cost: $600 |
- | - | - | - | - | - | $2,808 | 624 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,808 624 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,948 Cost: $2,800 |
$1,152 | 37,808 | $2,182 | 237 | - | - | $(-1,386) | (-308) | - | - |
$1,152 37,808 kWh |
$2,182 237 kW-months/year |
- - $ |
$(-1,386) (-308) MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $1,559 Cost: $1,550 |
$(-44) | (-1,465) | - | - | - | - | $1,603 | 356 | - | - |
$(-44) (-1,465) kWh |
- - kW-months/year |
- - $ |
$1,603 356 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,194 Cost: $1,800 |
$636 | 20,809 | $558 | 61 | - | - | - | - | - | - |
$636 20,809 kWh |
$558 61 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $156 Cost: $383 |
- | - | $156 | 18 | - | - | - | - | - | - |
- - kWh |
$156 18 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1132 REPAIR FAULTY LOUVERS AND DAMPERS |
Savings: $964 Cost: $1,100 |
- | - | - | - | - | - | $964 | 214 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$964 214 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5242 RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE |
Savings: $590 Cost: - |
- | - | - | - | - | - | - | - | $590 | 15,850 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$590 15,850 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $342 Cost: - |
- | - | - | - | $342 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$342 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $180 Cost: - |
- | - | - | - | - | - | - | - | $180 | 3,638 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$180 3,638 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $92 Cost: - |
$92 | 2,931 | - | - | - | - | - | - | - | - |
$92 2,931 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $9,833 Cost: $8,233 |
$1,836 | 60,083 | $2,896 | 316 | $342 | - | $3,989 | 886 | $770 | 19,488 | $1,836 60,083 kWh |
$2,896 316 kW-months/year |
$342 - $ |
$3,989 886 MMBtu |
$770 19,488 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,653 Cost: $3,950 |
$684 | 22,275 | $558 | 61 | - | - | $4,411 | 980 | - | - | $684 22,275 kWh |
$558 61 kW-months/year |
- - $ |
$4,411 980 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |