Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1997 |
Principal Product | Packaging Paper and Film |
NAICS | n/a |
SIC | 2571 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 114,750 |
Annual Production | 25,200,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $345,751 | 9,726,553 | kWh | $0.04 |
Electricity Demand | $283,333 | 22,049 | kW-months/year | $12.85 |
Electricity Fees | $39,508 | - | $ | - |
Natural Gas | $293,610 | 90,175 | MMBtu | $3.26 |
TOTAL ENERGY COSTS | $1,211,435 | |||
RECOMMENDED SAVINGS* | $63,993 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,780 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $17,900 Cost: - |
- | - | - | - | - | - | - | - | $17,900 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$17,900 - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $12,690 Cost: - |
- | - | - | - | - | - | - | - | - | 27,000 | - | - | - | - | $12,690 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- 27,000 lb |
- - $ |
- - $ |
$12,690 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $12,496 Cost: $11,150 |
$(-349) | (-9,379) | - | - | $12,845 | 3,940 | - | - | - | - | - | - | - | - | - | - | - | - |
$(-349) (-9,379) kWh |
- - kW-months/year |
$12,845 3,940 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $7,349 Cost: $22,000 |
$2,025 | 54,220 | $5,324 | 394 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$2,025 54,220 kWh |
$5,324 394 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7251 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF |
Savings: $6,780 Cost: $34,425 |
$4,744 | 126,905 | $5,359 | 396 | - | - | $(-3,323) | (-936,000) | - | - | - | - | - | - | - | - | - | - |
$4,744 126,905 kWh |
$5,359 396 kW-months/year |
- - MMBtu |
$(-3,323) (-936,000) Tgal |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $1,430 Cost: - |
- | - | - | - | - | - | - | - | - | - | $(-3,000) | - | $(-200) | - | - | - | $4,630 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
$(-3,000) - $ |
$(-200) - $ |
- - $ |
$4,630 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,219 Cost: $150 |
$1,599 | 42,790 | $620 | 46 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$1,599 42,790 kWh |
$620 46 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,588 Cost: $640 |
$1,020 | 27,257 | $568 | 42 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$1,020 27,257 kWh |
$568 42 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $1,541 Cost: $5,000 |
- | - | $973 | 72 | - | - | - | - | - | - | - | - | $568 | - | - | - | - | - |
- - kWh |
$973 72 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
$568 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $63,993 Cost: $73,365 |
$9,039 | 241,793 | $12,844 | 950 | $12,845 | 3,940 | $(-3,323) | (-936,000) | $17,900 | 27,000 | $(-3,000) | - | $368 | - | $12,690 | - | $4,630 | - | $9,039 241,793 kWh |
$12,844 950 kW-months/year |
$12,845 3,940 MMBtu |
$(-3,323) (-936,000) Tgal |
$17,900 27,000 lb |
$(-3,000) - $ |
$368 - $ |
$12,690 - $ |
$4,630 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,780 Cost: $5,150 |
$1,599 | 42,790 | $1,593 | 118 | - | - | - | - | $17,900 | 27,000 | $(-3,000) | - | $368 | - | $12,690 | - | $4,630 | - | $1,599 42,790 kWh |
$1,593 118 kW-months/year |
- - MMBtu |
- - Tgal |
$17,900 27,000 lb |
$(-3,000) - $ |
$368 - $ |
$12,690 - $ |
$4,630 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Ancillary Material Cost |