Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1997 |
Principal Product | Custom Sheet Metal Products |
NAICS | n/a |
SIC | 3444 - Sheet Metalwork |
Sales | $10,000,000-$50,000,000 |
# of Employees | 245 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,210 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $135,818 | 5,492,380 | kWh | $0.02 |
Electricity Demand | $120,577 | 14,780 | kW-months/year | $8.16 |
Electricity Fees | $4,750 | - | $ | - |
Natural Gas | $111,568 | 32,973 | MMBtu | $3.38 |
TOTAL ENERGY COSTS | $558,238 | |||
RECOMMENDED SAVINGS* | $60,753 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,021 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.452 ELIMINATE SHIFT |
Savings: $23,000 Cost: $5,000 |
- | - | - | - | - | - | - | - | $23,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$23,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,229 Cost: $20,892 |
$5,013 | 191,970 | $2,216 | 278 | - | - | - | - | - | - |
$5,013 191,970 kWh |
$2,216 278 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,099 Cost: $360 |
$4,922 | 188,453 | $2,177 | 273 | - | - | - | - | - | - |
$4,922 188,453 kWh |
$2,177 273 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $3,451 Cost: $10,000 |
- | - | - | - | $3,451 | 1,021 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,451 1,021 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,429 Cost: $740 |
$1,187 | 45,428 | $1,242 | 156 | - | - | - | - | - | - |
$1,187 45,428 kWh |
$1,242 156 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,693 Cost: - |
$1,693 | 64,771 | - | - | - | - | - | - | - | - |
$1,693 64,771 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $15,852 Cost: - |
- | - | - | - | - | - | $15,852 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$15,852 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $60,753 Cost: $36,992 |
$12,815 | 490,622 | $5,635 | 707 | $3,451 | 1,021 | $15,852 | - | $23,000 | - | $12,815 490,622 kWh |
$5,635 707 kW-months/year |
$3,451 1,021 MMBtu |
$15,852 - lb |
$23,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,021 Cost: $21,252 |
$11,628 | 445,194 | $4,393 | 551 | - | - | - | - | - | - | $11,628 445,194 kWh |
$4,393 551 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes |