IAC logo
IAC Assessment: WI0310
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0310
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1997
Principal Product Plastic Dials and Knobs
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 97
Plant Area (Sq.Ft.) 42,000
Annual Production 17,500,000 Pieces
Production Hrs. Annual 6,300
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $112,136 2,677,022 kWh $0.04
Electricity Demand $79,094 6,449 kW-months/year $12.26
Electricity Fees $4,107 - $ -
Natural Gas $7,550 1,556 MMBtu $4.85
TOTAL ENERGY COSTS $229,624
RECOMMENDED SAVINGS* $72,519 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,393
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Personnel Changes Electricity Usage Electricity Demand Electricity Fees Personnel Changes
$ kWh $ kW-months/year $ $ $ $
01: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT Savings:
$64,589
Cost:
$189,920
$(-2,886) (-68,875) $(-3,625) (-295) - - $71,100 - $(-2,886)
(-68,875)
kWh
$(-3,625)
(-295)
kW-months/year
-
-
$
$71,100
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$3,314
Cost:
$2,000
$1,694 40,445 $1,620 132 - - - - $1,694
40,445
kWh
$1,620
132
kW-months/year
-
-
$
-
-
$
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,061
Cost:
-
- - $2,111 172 - - $(-50) - -
-
kWh
$2,111
172
kW-months/year
-
-
$
$(-50)
-
$
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$601
Cost:
$2,500
- - $464 38 $137 - - - -
-
kWh
$464
38
kW-months/year
$137
-
$
-
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,332
Cost:
$397
$931 22,274 $401 32 - - - - $931
22,274
kWh
$401
32
kW-months/year
-
-
$
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$622
Cost:
$740
$296 7,034 $326 26 - - - - $296
7,034
kWh
$326
26
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$72,519
Cost:
$195,557
$35 878 $1,297 105 $137 - $71,050 - $35
878
kWh
$1,297
105
kW-months/year
$137
-
$
$71,050
-
$
TOTAL IMPLEMENTED Savings:
$3,393
Cost:
$397
$931 22,274 $2,512 204 - - $(-50) - $931
22,274
kWh
$2,512
204
kW-months/year
-
-
$
$(-50)
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Personnel Changes Electricity Usage Electricity Demand Electricity Fees Personnel Changes