Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1998 |
Principal Product | Lithographic Commercial Printing |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 110,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,000 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $126,660 | 2,960,141 | kWh | $0.04 |
Electricity Demand | $97,499 | 8,002 | kW-months/year | $12.18 |
Electricity Fees | $2,424 | - | $ | - |
Natural Gas | $29,891 | 6,384 | MMBtu | $4.68 |
TOTAL ENERGY COSTS | $268,271 | |||
RECOMMENDED SAVINGS* | $205,921 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,945 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $147,023 Cost: - |
- | - | - | - | - | - | $944 | 17,395 | - | - | $146,079 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$944 17,395 lb |
- - $ |
$146,079 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $30,000 Cost: - |
- | - | - | - | - | - | - | - | $30,000 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$30,000 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $15,000 Cost: $6,350 |
- | - | - | - | - | - | - | - | $15,000 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$15,000 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $4,880 Cost: $10,000 |
$(-22) | (-586) | - | - | - | - | - | - | - | - | - | - | $4,902 | - |
$(-22) (-586) kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
$4,902 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $3,605 Cost: $4,000 |
$1,907 | 42,204 | $1,698 | 132 | - | - | - | - | - | - | - | - | - | - |
$1,907 42,204 kWh |
$1,698 132 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $2,567 Cost: - |
- | - | - | - | - | - | $2,567 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,567 - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $1,520 Cost: - |
$(-4) | (-293) | - | - | - | - | $2,274 | 16,752 | $(-750) | - | - | - | - | - |
$(-4) (-293) kWh |
- - kW-months/year |
- - MMBtu |
$2,274 16,752 lb |
$(-750) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $820 Cost: $1,332 |
- | - | - | - | $820 | 175 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$820 175 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $506 Cost: $640 |
$431 | 9,672 | $75 | 16 | - | - | - | - | - | - | - | - | - | - |
$431 9,672 kWh |
$75 16 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $205,921 Cost: $22,322 |
$2,312 | 50,997 | $1,773 | 148 | $820 | 175 | $5,785 | 34,147 | $44,250 | - | $146,079 | - | $4,902 | - | $2,312 50,997 kWh |
$1,773 148 kW-months/year |
$820 175 MMBtu |
$5,785 34,147 lb |
$44,250 - $ |
$146,079 - $ |
$4,902 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,945 Cost: $5,332 |
$1,903 | 41,911 | $1,698 | 132 | $820 | 175 | $2,274 | 16,752 | $29,250 | - | - | - | - | - | $1,903 41,911 kWh |
$1,698 132 kW-months/year |
$820 175 MMBtu |
$2,274 16,752 lb |
$29,250 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Ancillary Material Cost |