Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1998 |
Principal Product | Slurry Pumps |
NAICS | n/a |
SIC | 3561 - Pumps And Pumping Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 77,000 |
Annual Production | 1,440 Pieces |
Production Hrs. Annual | 6,480 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $82,468 | 2,787,222 | kWh | $0.03 |
Electricity Demand | $78,305 | 11,043 | kW-months/year | $7.09 |
Electricity Fees | $10,036 | - | $ | - |
Natural Gas | $33,748 | 7,012 | MMBtu | $4.81 |
TOTAL ENERGY COSTS | $229,663 | |||
RECOMMENDED SAVINGS* | $56,238 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $38,962 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $22,908 Cost: $1,500 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $22,908 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
$22,908 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $14,336 Cost: - |
- | - | $14,808 | 1,977 | - | - | - | - | - | - | $(-472) | - | - | - | - | - |
- - kWh |
$14,808 1,977 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
$(-472) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $1,092 Cost: $400 |
- | - | $1,092 | 146 | - | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$1,092 146 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $10,231 Cost: $11,400 |
- | - | - | - | - | - | $12,472 | - | $(-542) | (-366) | $(-1,119) | - | - | - | $(-580) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$12,472 - gal |
$(-542) (-366) lb |
$(-1,119) - $ |
- - $ |
$(-580) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.231 PURCHASE EQUIPMENT INSTEAD OF LEASING |
Savings: $3,600 Cost: $9,500 |
- | - | - | - | - | - | - | - | - | - | - | - | $3,600 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
$3,600 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $3,445 Cost: $1,600 |
- | - | - | - | $3,445 | 716 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,445 716 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $626 Cost: $640 |
$470 | 14,947 | $156 | 21 | - | - | - | - | - | - | - | - | - | - | - | - |
$470 14,947 kWh |
$156 21 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $56,238 Cost: $25,040 |
$470 | 14,947 | $16,056 | 2,144 | $3,445 | 716 | $12,472 | - | $(-542) | (-366) | $(-1,591) | - | $3,600 | - | $22,328 | - | $470 14,947 kWh |
$16,056 2,144 kW-months/year |
$3,445 716 MMBtu |
$12,472 - gal |
$(-542) (-366) lb |
$(-1,591) - $ |
$3,600 - $ |
$22,328 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $38,962 Cost: $2,540 |
$470 | 14,947 | $16,056 | 2,144 | - | - | - | - | - | - | $(-472) | - | - | - | $22,908 | - | $470 14,947 kWh |
$16,056 2,144 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
$(-472) - $ |
- - $ |
$22,908 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material |