Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1999 |
Principal Product | Power Conditioners |
NAICS | n/a |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $10,000,000-$50,000,000 |
# of Employees | 170 |
Plant Area (Sq.Ft.) | 107,120 |
Annual Production | 1,045,000 Pieces |
Production Hrs. Annual | 2,125 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $51,255 | 1,472,743 | kWh | $0.03 |
Electricity Demand | $48,768 | 3,933 | kW-months/year | $12.40 |
Electricity Fees | $4,764 | - | $ | - |
Natural Gas | $15,418 | 3,781 | MMBtu | $4.08 |
TOTAL ENERGY COSTS | $141,508 | |||
RECOMMENDED SAVINGS* | $14,468 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,934 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $3,909 Cost: - |
- | - | $3,909 | 300 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$3,909 300 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $245 Cost: $300 |
- | - | $245 | - | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$245 - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,824 Cost: $1,000 |
- | - | - | - | - | - | - | - | $2,824 | 126,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$2,824 126,000 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,826 Cost: $2,400 |
$475 | 12,896 | $1,351 | 104 | - | - | - | - | - | - | - | - | - | - |
$475 12,896 kWh |
$1,351 104 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $2,534 Cost: $4,000 |
- | - | - | - | - | - | $1,320 | 165 | $(-131) | (-73) | $(-264) | - | $1,609 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,320 165 gal |
$(-131) (-73) lb |
$(-264) - $ |
$1,609 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $1,865 Cost: $2,000 |
$883 | 24,033 | $982 | 75 | - | - | - | - | - | - | - | - | - | - |
$883 24,033 kWh |
$982 75 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $826 Cost: $2,600 |
$(-65) | (-1,758) | - | - | $891 | 218 | - | - | - | - | - | - | - | - |
$(-65) (-1,758) kWh |
- - kW-months/year |
$891 218 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $439 Cost: - |
- | - | - | - | $439 | 108 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$439 108 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $14,468 Cost: $12,300 |
$1,293 | 35,171 | $6,487 | 479 | $1,330 | 326 | $1,320 | 165 | $2,693 | 125,927 | $(-264) | - | $1,609 | - | $1,293 35,171 kWh |
$6,487 479 kW-months/year |
$1,330 326 MMBtu |
$1,320 165 gal |
$2,693 125,927 lb |
$(-264) - $ |
$1,609 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,934 Cost: $3,300 |
$883 | 24,033 | $1,227 | 75 | - | - | - | - | $2,824 | 126,000 | - | - | - | - | $883 24,033 kWh |
$1,227 75 kW-months/year |
- - MMBtu |
- - gal |
$2,824 126,000 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material |