Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1999 |
Principal Product | Fruit Juices and Concentrates |
NAICS | n/a |
SIC | 2037 - Frozen Fruits And Vegetables |
Sales | $100,000,000-$500,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 170,000 |
Annual Production | 15,000 Thousand Gallons |
Production Hrs. Annual | 6,000 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $400,758 | 11,949,297 | kWh | $0.03 |
Electricity Demand | $293,315 | 21,104 | kW-months/year | $13.90 |
Electricity Fees | $104,922 | - | $ | - |
Natural Gas | $68,722 | 19,033 | MMBtu | $3.61 |
TOTAL ENERGY COSTS | $988,392 | |||
RECOMMENDED SAVINGS* | $342,377 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,224 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $128,017 Cost: $420,000 |
$127,080 | 3,599,941 | $105,336 | 7,200 | $(-100,199) | (-27,756) | $(-4,200) | - |
$127,080 3,599,941 kWh |
$105,336 7,200 kW-months/year |
$(-100,199) (-27,756) MMBtu |
$(-4,200) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,551 Cost: $500 |
- | - | - | - | $5,551 | 1,538 | - | - |
- - kWh |
- - kW-months/year |
$5,551 1,538 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $129,034 Cost: $30,000 |
$(-474) | (-13,482) | $(-492) | (-34) | - | - | $130,000 | - |
$(-474) (-13,482) kWh |
$(-492) (-34) kW-months/year |
- - MMBtu |
$130,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $65,000 Cost: $140,000 |
- | - | - | - | - | - | $65,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$65,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $10,102 Cost: $6,600 |
- | - | $10,102 | 416 | - | - | - | - |
- - kWh |
$10,102 416 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,189 Cost: $1,480 |
$1,350 | 38,101 | $839 | 57 | - | - | - | - |
$1,350 38,101 kWh |
$839 57 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,593 Cost: $508 |
$1,004 | 28,429 | $589 | 40 | - | - | - | - |
$1,004 28,429 kWh |
$589 40 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $891 Cost: $1,400 |
$399 | 11,430 | $492 | 34 | - | - | - | - |
$399 11,430 kWh |
$492 34 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $342,377 Cost: $600,488 |
$129,359 | 3,664,419 | $116,866 | 7,713 | $(-94,648) | (-26,218) | $190,800 | - | $129,359 3,664,419 kWh |
$116,866 7,713 kW-months/year |
$(-94,648) (-26,218) MMBtu |
$190,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,224 Cost: $3,888 |
$2,753 | 77,960 | $1,920 | 131 | $5,551 | 1,538 | - | - | $2,753 77,960 kWh |
$1,920 131 kW-months/year |
$5,551 1,538 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |