Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 1999 |
Principal Product | Metal Stampings |
NAICS | n/a |
SIC | 3462 - Iron And Steel Forgings |
Sales | $50,000,000-$100,000,000 |
# of Employees | 173 |
Plant Area (Sq.Ft.) | 104,570 |
Annual Production | 6,000,000 Pieces |
Production Hrs. Annual | 6,500 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $72,576 | 2,088,804 | kWh | $0.03 |
Electricity Demand | $61,257 | 4,942 | kW-months/year | $12.40 |
Electricity Fees | $13,504 | - | $ | - |
Natural Gas | $12,218 | 2,917 | MMBtu | $4.19 |
TOTAL ENERGY COSTS | $(-175,291) | |||
RECOMMENDED SAVINGS* | $183,847 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,061 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $168,000 Cost: $35,000 |
- | - | - | - | - | - | - | - | $168,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$168,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $7,386 Cost: - |
- | - | - | - | - | - | $7,386 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$7,386 - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,327 Cost: $3,116 |
$1,721 | 44,842 | $1,606 | 118 | - | - | - | - | - | - | - | - |
$1,721 44,842 kWh |
$1,606 118 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,549 Cost: $9,000 |
$(-6) | (-293) | - | - | - | - | $3,255 | 93,000 | $(-700) | - | - | - |
$(-6) (-293) kWh |
- - kW-months/year |
- - MMBtu |
$3,255 93,000 lb |
$(-700) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.7137 REPLACE CLOTH RAGS WITH PAPER TOWELS |
Savings: $1,037 Cost: - |
- | - | - | - | - | - | - | - | - | - | $1,037 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$1,037 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $910 Cost: $2,500 |
- | - | $910 | 67 | - | - | - | - | - | - | - | - |
- - kWh |
$910 67 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $638 Cost: $1,000 |
- | - | - | - | $638 | 152 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$638 152 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $183,847 Cost: $50,616 |
$1,715 | 44,549 | $2,516 | 185 | $638 | 152 | $10,641 | 93,000 | $167,300 | - | $1,037 | - | $1,715 44,549 kWh |
$2,516 185 kW-months/year |
$638 152 MMBtu |
$10,641 93,000 lb |
$167,300 - $ |
$1,037 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,061 Cost: $1,000 |
- | - | - | - | $638 | 152 | $7,386 | - | - | - | $1,037 | - | - - kWh |
- - kW-months/year |
$638 152 MMBtu |
$7,386 - lb |
- - $ |
$1,037 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes |