Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2001 |
Principal Product | Printed Plastic Packaging |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 30,000 |
Annual Production | 3,600,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $51,364 | 1,577,203 | kWh | $0.03 |
Electricity Demand | $31,944 | 3,612 | kW-months/year | $8.84 |
Electricity Fees | $5,628 | - | $ | - |
Natural Gas | $50,718 | 8,330 | MMBtu | $6.09 |
TOTAL ENERGY COSTS | $148,166 | |||
RECOMMENDED SAVINGS* | $43,164 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $19,159 Cost: $14,000 |
- | - | - | - | - | - | - | - | $28,706 | 7,002 | $(-2,368) | (-3,051) | $(-7,179) | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$28,706 7,002 gal |
$(-2,368) (-3,051) lb |
$(-7,179) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $10,173 Cost: $19,500 |
$(-515) | (-14,976) | $(-280) | (-30) | - | - | $10,968 | 4,099,950 | - | - | - | - | - | - | - | - |
$(-515) (-14,976) kWh |
$(-280) (-30) kW-months/year |
- - MMBtu |
$10,968 4,099,950 Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $9,162 Cost: $11,500 |
- | - | - | - | $9,162 | 1,505 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,162 1,505 MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,714 Cost: $7,393 |
$1,218 | 35,388 | $496 | 53 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,218 35,388 kWh |
$496 53 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $147 Cost: $75 |
$147 | 4,263 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$147 4,263 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7131 USE A RAG RECYCLE SERVICE |
Savings: $1,404 Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $1,404 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
$1,404 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $820 Cost: $640 |
$583 | 16,955 | $237 | 25 | - | - | - | - | - | - | - | - | - | - | - | - |
$583 16,955 kWh |
$237 25 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $585 Cost: $403 |
$428 | 12,433 | $157 | 17 | - | - | - | - | - | - | - | - | - | - | - | - |
$428 12,433 kWh |
$157 17 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,164 Cost: $53,511 |
$1,861 | 54,063 | $610 | 65 | $9,162 | 1,505 | $10,968 | 4,099,950 | $28,706 | 7,002 | $(-2,368) | (-3,051) | $(-7,179) | - | $1,404 | - | $1,861 54,063 kWh |
$610 65 kW-months/year |
$9,162 1,505 MMBtu |
$10,968 4,099,950 Tgal |
$28,706 7,002 gal |
$(-2,368) (-3,051) lb |
$(-7,179) - $ |
$1,404 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes |