Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2001 |
Principal Product | Flexible Packaging Products |
NAICS | n/a |
SIC | 2672 - Paper Coated And Laminated, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 133,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 8,760 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $197,751 | 7,182,022 | kWh | $0.03 |
Electricity Demand | $152,319 | 16,502 | kW-months/year | $9.23 |
Electricity Fees | $24,933 | - | $ | - |
Natural Gas | $202,922 | 57,587 | MMBtu | $3.52 |
TOTAL ENERGY COSTS | $577,925 | |||
RECOMMENDED SAVINGS* | $242,156 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $172,934 Cost: $560,000 |
$202,531 | 7,008,000 | $93,024 | 9,600 | $(-120,874) | (-34,339) | $(-1,747) | - | - | - |
$202,531 7,008,000 kWh |
$93,024 9,600 kW-months/year |
$(-120,874) (-34,339) MMBtu |
$(-1,747) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $40,600 Cost: $10,000 |
- | - | - | - | - | - | $40,600 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$40,600 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.7131 USE A RAG RECYCLE SERVICE |
Savings: $11,777 Cost: - |
- | - | - | - | - | - | - | - | $11,777 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$11,777 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $6,365 Cost: $4,500 |
$4,734 | 163,798 | $1,631 | 168 | - | - | - | - | - | - |
$4,734 163,798 kWh |
$1,631 168 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,350 Cost: - |
$1,004 | 34,732 | $346 | 36 | - | - | - | - | - | - |
$1,004 34,732 kWh |
$346 36 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $5,004 Cost: $1,920 |
$3,588 | 124,164 | $1,416 | 146 | - | - | - | - | - | - |
$3,588 124,164 kWh |
$1,416 146 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,983 Cost: $1,000 |
- | - | - | - | $3,983 | 1,131 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,983 1,131 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $143 Cost: $30 |
$106 | 3,660 | $37 | 4 | - | - | - | - | - | - |
$106 3,660 kWh |
$37 4 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $242,156 Cost: $577,450 |
$211,963 | 7,334,354 | $96,454 | 9,954 | $(-116,891) | (-33,208) | $38,853 | - | $11,777 | - | $211,963 7,334,354 kWh |
$96,454 9,954 kW-months/year |
$(-116,891) (-33,208) MMBtu |
$38,853 - $ |
$11,777 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||