Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2001 |
Principal Product | Food Service Equipment |
NAICS | n/a |
SIC | 3589 - Service Industry Machinery, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 290 |
Plant Area (Sq.Ft.) | 212,000 |
Annual Production | 100,000 Pieces |
Production Hrs. Annual | 6,075 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $111,586 | 3,624,471 | kWh | $0.03 |
Electricity Demand | $55,405 | 10,407 | kW-months/year | $5.32 |
Electricity Fees | $18,972 | - | $ | - |
Natural Gas | $45,257 | 8,962 | MMBtu | $5.05 |
TOTAL ENERGY COSTS | $197,481 | |||
RECOMMENDED SAVINGS* | $21,394 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,138 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $8,173 Cost: - |
- | - | - | - | - | - | - | - | $8,173 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$8,173 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $3,674 Cost: $7,700 |
- | - | - | - | - | - | $4,756 | 481 | $(-288) | (-161) | $(-481) | - | $(-313) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,756 481 gal |
$(-288) (-161) lb |
$(-481) - $ |
$(-313) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.3131 USE EVAPORATION TO CONCENTRATE MATERIAL |
Savings: $3,585 Cost: $10,000 |
- | - | - | - | $(-104) | (-21) | $4,289 | 2,121 | - | - | $(-600) | - | - | - |
- - kWh |
- - kW-months/year |
$(-104) (-21) MMBtu |
$4,289 2,121 gal |
- - lb |
$(-600) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $2,972 Cost: $6,675 |
$2,972 | 92,022 | - | - | - | - | - | - | - | - | - | - | - | - |
$2,972 92,022 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,025 Cost: $2,400 |
$427 | 13,222 | $598 | 107 | - | - | - | - | - | - | - | - | - | - |
$427 13,222 kWh |
$598 107 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $813 Cost: - |
$813 | 25,178 | - | - | - | - | - | - | - | - | - | - | - | - |
$813 25,178 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $650 Cost: $640 |
$523 | 16,186 | $127 | 23 | - | - | - | - | - | - | - | - | - | - |
$523 16,186 kWh |
$127 23 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $502 Cost: - |
- | - | $502 | 101 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$502 101 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $21,394 Cost: $27,415 |
$4,735 | 146,608 | $1,227 | 231 | $(-104) | (-21) | $9,045 | 2,602 | $7,885 | (-161) | $(-1,081) | - | $(-313) | - | $4,735 146,608 kWh |
$1,227 231 kW-months/year |
$(-104) (-21) MMBtu |
$9,045 2,602 gal |
$7,885 (-161) lb |
$(-1,081) - $ |
$(-313) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,138 Cost: $640 |
$1,336 | 41,364 | $629 | 124 | - | - | - | - | $8,173 | - | - | - | - | - | $1,336 41,364 kWh |
$629 124 kW-months/year |
- - MMBtu |
- - gal |
$8,173 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material |