Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2001 |
Principal Product | Mining Equipment |
NAICS | n/a |
SIC | 3532 - Mining Machinery |
Sales | $50,000,000-$100,000,000 |
# of Employees | 182 |
Plant Area (Sq.Ft.) | 138,000 |
Annual Production | 200 Pieces |
Production Hrs. Annual | 4,125 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $91,607 | 3,498,692 | kWh | $0.03 |
Electricity Demand | $73,311 | 7,799 | kW-months/year | $9.40 |
Electricity Fees | $16,057 | - | $ | - |
Natural Gas | $137,343 | 24,907 | MMBtu | $5.51 |
TOTAL ENERGY COSTS | $339,941 | |||
RECOMMENDED SAVINGS* | $108,903 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $31,173 Cost: $2,000 |
- | - | - | - | $31,173 | 5,658 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$31,173 5,658 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $10,170 Cost: $8,874 |
$(-361) | (-13,090) | - | - | $10,531 | 1,911 | - | - | - | - | - | - | - | - | - | - |
$(-361) (-13,090) kWh |
- - kW-months/year |
$10,531 1,911 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $24,740 Cost: - |
- | - | $25,053 | 2,592 | - | - | - | - | - | - | $(-313) | - | - | - | - | - |
- - kWh |
$25,053 2,592 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
$(-313) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $10,208 Cost: $4,500 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $10,208 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
$10,208 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $12,894 Cost: $62,046 |
$5,749 | 208,313 | $7,145 | 909 | - | - | - | - | - | - | - | - | - | - | - | - |
$5,749 208,313 kWh |
$7,145 909 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $6,914 Cost: $4,000 |
- | - | - | - | - | - | $4,363 | 990 | $(-582) | (-347) | $(-2,045) | - | - | - | $5,178 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,363 990 gal |
$(-582) (-347) lb |
$(-2,045) - $ |
- - $ |
$5,178 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7137 REPLACE CLOTH RAGS WITH PAPER TOWELS |
Savings: $6,301 Cost: - |
- | - | - | - | - | - | - | - | $(-78) | (-6,528) | - | - | $6,379 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$(-78) (-6,528) lb |
- - $ |
$6,379 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $3,805 Cost: $11,500 |
- | - | - | - | $3,805 | 691 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,805 691 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $1,549 Cost: - |
- | - | - | - | - | - | - | - | $1,549 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$1,549 - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,149 Cost: $2,009 |
$542 | 19,634 | $607 | 77 | - | - | - | - | - | - | - | - | - | - | - | - |
$542 19,634 kWh |
$607 77 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $108,903 Cost: $94,929 |
$5,930 | 214,857 | $32,805 | 3,578 | $45,509 | 8,260 | $4,363 | 990 | $889 | (-6,875) | $(-2,358) | - | $6,379 | - | $15,386 | - | $5,930 214,857 kWh |
$32,805 3,578 kW-months/year |
$45,509 8,260 MMBtu |
$4,363 990 gal |
$889 (-6,875) lb |
$(-2,358) - $ |
$6,379 - $ |
$15,386 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material |