Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2001 |
Principal Product | Envelopes and Stationery |
NAICS | n/a |
SIC | 2675 - Die-cut Paper And Board |
Sales | $10,000,000-$50,000,000 |
# of Employees | 85 |
Plant Area (Sq.Ft.) | 121,250 |
Annual Production | 400,000,000 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $38,593 | 1,025,680 | kWh | $0.04 |
Electricity Demand | $45,565 | 5,047 | kW-months/year | $9.03 |
Electricity Fees | $6,799 | - | $ | - |
TOTAL ENERGY COSTS | $(-133,979) | |||
RECOMMENDED SAVINGS* | $18,503 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,135 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $12,000 Cost: - |
- | - | - | - | - | - | - | - | - | - | $12,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$12,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $3,918 Cost: $14,500 |
$(-158) | (-3,991) | $(-229) | (-24) | - | - | - | - | $4,305 | 1,345,950 | - | - |
$(-158) (-3,991) kWh |
$(-229) (-24) kW-months/year |
- - $ |
- - MMBtu |
$4,305 1,345,950 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $798 Cost: $2,400 |
$384 | 9,667 | $414 | 43 | - | - | - | - | - | - | - | - |
$384 9,667 kWh |
$414 43 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $728 Cost: $1,190 |
$360 | 9,056 | $368 | 39 | - | - | - | - | - | - | - | - |
$360 9,056 kWh |
$368 39 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $668 Cost: $1,600 |
$(-41) | (-1,027) | - | - | - | - | $709 | 84 | - | - | - | - |
$(-41) (-1,027) kWh |
- - kW-months/year |
- - $ |
$709 84 MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $256 Cost: $640 |
$126 | 3,179 | $130 | 14 | - | - | - | - | - | - | - | - |
$126 3,179 kWh |
$130 14 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $135 Cost: $400 |
- | - | - | - | $135 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$135 - $ |
- - MMBtu |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,503 Cost: $20,730 |
$671 | 16,884 | $683 | 72 | $135 | - | $709 | 84 | $4,305 | 1,345,950 | $12,000 | - | $671 16,884 kWh |
$683 72 kW-months/year |
$135 - $ |
$709 84 MMBtu |
$4,305 1,345,950 Tgal |
$12,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,135 Cost: $400 |
- | - | - | - | $135 | - | - | - | - | - | $12,000 | - | - - kWh |
- - kW-months/year |
$135 - $ |
- - MMBtu |
- - Tgal |
$12,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes |