Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2002 |
Principal Product | Plastic Wrapping Material |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 53,800 |
Annual Production | 7,274,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $136,335 | 3,856,020 | kWh | $0.04 |
Electricity Demand | $88,452 | 8,519 | kW-months/year | $10.38 |
Electricity Fees | $18,880 | - | $ | - |
Natural Gas | $222,544 | 38,024 | MMBtu | $5.85 |
TOTAL ENERGY COSTS | $500,711 | |||
RECOMMENDED SAVINGS* | $54,805 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $928 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.6122 INSTALL SOLID WASTE INCINERATOR FOR HEAT |
Savings: $27,075 Cost: $130,000 |
- | - | - | - | - | - | $27,075 | 5,700 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$27,075 5,700 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $8,951 Cost: $3,762 |
$6,737 | 208,880 | $2,214 | 202 | - | - | - | - |
$6,737 208,880 kWh |
$2,214 202 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $6,493 Cost: $600 |
$(-281) | (-7,546) | - | - | $6,774 | 1,158 | - | - |
$(-281) (-7,546) kWh |
- - kW-months/year |
$6,774 1,158 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $6,626 Cost: $26,500 |
- | - | - | - | $6,626 | 11,326 | - | - |
- - kWh |
- - kW-months/year |
$6,626 11,326 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,732 Cost: $25,405 |
$2,504 | 67,320 | $2,228 | 173 | - | - | - | - |
$2,504 67,320 kWh |
$2,228 173 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $928 Cost: $640 |
$706 | 18,974 | $222 | 20 | - | - | - | - |
$706 18,974 kWh |
$222 20 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $54,805 Cost: $186,907 |
$9,666 | 287,628 | $4,664 | 395 | $13,400 | 12,484 | $27,075 | 5,700 | $9,666 287,628 kWh |
$4,664 395 kW-months/year |
$13,400 12,484 MMBtu |
$27,075 5,700 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $928 Cost: $640 |
$706 | 18,974 | $222 | 20 | - | - | - | - | $706 18,974 kWh |
$222 20 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) |