IAC logo
IAC Assessment: WI0430
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0430
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2002
Principal Product Currugated Boxes
NAICS n/a
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 200,000
Annual Production 1,100,000,000 Thousand Feet
Production Hrs. Annual 6,000
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $133,466 4,859,250 kWh $0.03
Electricity Demand $84,234 10,789 kW-months/year $7.81
Electricity Fees $45,897 - $ -
Natural Gas $481,174 62,790 MMBtu $7.66
TOTAL ENERGY COSTS $746,523
RECOMMENDED SAVINGS* $38,415 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,430
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$24,059
Cost:
$25,000
- - - - $24,059 3,137 -
-
kWh
-
-
kW-months/year
$24,059
3,137
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$6,072
Cost:
$18,000
$3,867 134,280 $2,205 268 - - $3,867
134,280
kWh
$2,205
268
kW-months/year
-
-
MMBtu
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,938
Cost:
$11,250
- - - - $4,938 645 -
-
kWh
-
-
kW-months/year
$4,938
645
MMBtu
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,916
Cost:
$1,549
$1,260 43,765 $656 80 - - $1,260
43,765
kWh
$656
80
kW-months/year
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$741
Cost:
-
$471 16,365 $270 33 - - $471
16,365
kWh
$270
33
kW-months/year
-
-
MMBtu
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$689
Cost:
$39
- - - - $689 90 -
-
kWh
-
-
kW-months/year
$689
90
MMBtu
TOTAL RECOMMENDED Savings:
$38,415
Cost:
$55,838
$5,598 194,410 $3,131 381 $29,686 3,872 $5,598
194,410
kWh
$3,131
381
kW-months/year
$29,686
3,872
MMBtu
TOTAL IMPLEMENTED Savings:
$1,430
Cost:
$39
$471 16,365 $270 33 $689 90 $471
16,365
kWh
$270
33
kW-months/year
$689
90
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas