Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2002 |
Principal Product | stainless utensils |
NAICS | n/a |
SIC | 3421 - Cutlery |
Sales | $100,000,000-$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 610,000 |
Annual Production | 20,000,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $272,521 | 12,700,800 | kWh | $0.02 |
Electricity Demand | $203,106 | 27,223 | kW-months/year | $7.46 |
Electricity Fees | $135,852 | - | $ | - |
Natural Gas | $435,878 | 107,033 | MMBtu | $4.07 |
TOTAL ENERGY COSTS | $1,262,719 | |||
RECOMMENDED SAVINGS* | $156,166 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,915 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.3132 USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL |
Savings: $133,384 Cost: $140,000 |
$(-2,400) | (-50,000) | - | - | $142,284 | 85,200,000 | $(-6,500) | - |
$(-2,400) (-50,000) kWh |
- - kW-months/year |
$142,284 85,200,000 Tgal |
$(-6,500) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $9,841 Cost: $25,000 |
$4,935 | 219,324 | $4,906 | 627 | - | - | - | - |
$4,935 219,324 kWh |
$4,906 627 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,168 Cost: $11,700 |
$5,168 | 229,698 | - | - | - | - | - | - |
$5,168 229,698 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,746 Cost: $12,600 |
$3,746 | 166,507 | - | - | - | - | - | - |
$3,746 166,507 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,556 Cost: $740 |
$931 | 41,382 | $625 | 80 | - | - | - | - |
$931 41,382 kWh |
$625 80 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,280 Cost: $2,832 |
$806 | 35,808 | $474 | 61 | - | - | - | - |
$806 35,808 kWh |
$474 61 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,191 Cost: $588 |
$702 | 31,200 | $489 | 62 | - | - | - | - |
$702 31,200 kWh |
$489 62 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $156,166 Cost: $193,460 |
$13,888 | 673,919 | $6,494 | 830 | $142,284 | 85,200,000 | $(-6,500) | - | $13,888 673,919 kWh |
$6,494 830 kW-months/year |
$142,284 85,200,000 Tgal |
$(-6,500) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,915 Cost: $13,028 |
$6,801 | 302,280 | $1,114 | 142 | - | - | - | - | $6,801 302,280 kWh |
$1,114 142 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes |