Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2003 |
Principal Product | Metal Cans |
NAICS | 332431 - Metal Can Manufacturing |
SIC | 3411 - Metal Cans |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 0 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $204,335 | 6,815,077 | kWh | $0.03 |
Electricity Demand | $127,396 | 14,086 | kW-months/year | $9.04 |
Electricity Fees | $13,555 | - | $ | - |
Natural Gas | $406,731 | 64,109 | MMBtu | $6.34 |
TOTAL ENERGY COSTS | $762,617 | |||
RECOMMENDED SAVINGS* | $93,859 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,162 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $47,771 Cost: $18,500 |
- | - | - | - | $47,771 | 7,535 | - | - |
- - kWh |
- - kW-months/year |
$47,771 7,535 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $22,445 Cost: $40,000 |
$33,699 | 1,063,050 | $19,463 | 2,038 | $(-30,717) | (-4,845) | - | - |
$33,699 1,063,050 kWh |
$19,463 2,038 kW-months/year |
$(-30,717) (-4,845) MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,041 Cost: $18,315 |
$7,513 | 237,018 | $4,528 | 474 | - | - | - | - |
$7,513 237,018 kWh |
$4,528 474 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $3,824 Cost: $8,700 |
$(-1,137) | (-22,380) | - | - | - | - | $4,961 | 1,560,000 |
$(-1,137) (-22,380) kWh |
- - kW-months/year |
- - MMBtu |
$4,961 1,560,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,121 Cost: $1,280 |
$2,147 | 67,724 | $974 | 102 | - | - | - | - |
$2,147 67,724 kWh |
$974 102 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $4,657 Cost: $20,000 |
$2,906 | 91,665 | $1,751 | 183 | - | - | - | - |
$2,906 91,665 kWh |
$1,751 183 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $93,859 Cost: $106,795 |
$45,128 | 1,437,077 | $26,716 | 2,797 | $17,054 | 2,690 | $4,961 | 1,560,000 | $45,128 1,437,077 kWh |
$26,716 2,797 kW-months/year |
$17,054 2,690 MMBtu |
$4,961 1,560,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,162 Cost: $19,595 |
$9,660 | 304,742 | $5,502 | 576 | - | - | - | - | $9,660 304,742 kWh |
$5,502 576 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |