IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2004 |
Principal Product | Blinds |
NAICS | 337920 - Blind and Shade Manufacturing |
SIC | 2591 - Drapery Hardware & Blinds & Shades |
Sales | $50,000,000-$100,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 420,000,000 Pieces |
Production Hrs. Annual | 8,400 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $554,870 | 15,684,787 | kWh | $0.04 |
Electricity Demand | $286,959 | 30,181 | kW-months/year | $9.51 |
Electricity Fees | $53,929 | - | $ | - |
Natural Gas | $304,940 | 41,853 | MMBtu | $7.29 |
TOTAL ENERGY COSTS | $1,350,284 | |||
RECOMMENDED SAVINGS* | $148,891 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $75,927 Cost: $18,500 |
$(-4,854) | (-930,996) | - | - | - | - | $80,781 | 34,670,000 |
$(-4,854) (-930,996) kWh |
- - kW-months/year |
- - MMBtu |
$80,781 34,670,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $17,690 Cost: $17,690 |
- | - | - | - | $17,690 | 2,427 | - | - |
- - kWh |
- - kW-months/year |
$17,690 2,427 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $15,360 Cost: $2,000 |
- | - | - | - | $15,360 | 2,108 | - | - |
- - kWh |
- - kW-months/year |
$15,360 2,108 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,859 Cost: $29,148 |
$10,002 | 268,162 | $3,857 | 383 | - | - | - | - |
$10,002 268,162 kWh |
$3,857 383 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $11,920 Cost: $12,595 |
$11,920 | 319,586 | - | - | - | - | - | - |
$11,920 319,586 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $7,605 Cost: $840 |
$5,231 | 140,245 | $2,374 | 236 | - | - | - | - |
$5,231 140,245 kWh |
$2,374 236 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,530 Cost: $15,200 |
$6,530 | 175,104 | - | - | - | - | - | - |
$6,530 175,104 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $148,891 Cost: $95,973 |
$28,829 | (-27,899) | $6,231 | 619 | $33,050 | 4,535 | $80,781 | 34,670,000 | $28,829 (-27,899) kWh |
$6,231 619 kW-months/year |
$33,050 4,535 MMBtu |
$80,781 34,670,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |