Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2004 |
Principal Product | Sorbent Materials for industrial use |
NAICS | 325612 - Polish and Other Sanitation Good Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 6,400,000 Pounds |
Production Hrs. Annual | 4,300 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $44,674 | 1,581,760 | kWh | $0.03 |
Electricity Demand | $28,789 | 4,059 | kW-months/year | $7.09 |
Electricity Fees | $4,802 | - | $ | - |
Natural Gas | $9,789 | 1,262 | MMBtu | $7.76 |
TOTAL ENERGY COSTS | $94,152 | |||
RECOMMENDED SAVINGS* | $27,718 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,716 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,751 Cost: $48,510 |
$9,498 | 318,729 | $6,253 | 836 | - | - | - | - |
$9,498 318,729 kWh |
$6,253 836 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $3,969 Cost: $6,500 |
$(-286) | (-9,623) | $(-90) | (-12) | - | - | $4,345 | 822,938 |
$(-286) (-9,623) kWh |
$(-90) (-12) kW-months/year |
- - MMBtu |
$4,345 822,938 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,856 Cost: - |
$2,268 | 76,082 | $1,588 | 212 | - | - | - | - |
$2,268 76,082 kWh |
$1,588 212 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,860 Cost: $1,000 |
- | - | - | - | $1,860 | 240 | - | - |
- - kWh |
- - kW-months/year |
$1,860 240 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,256 Cost: $428 |
$854 | 28,667 | $402 | 54 | - | - | - | - |
$854 28,667 kWh |
$402 54 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $468 Cost: - |
$275 | 9,238 | $193 | 26 | - | - | - | - |
$275 9,238 kWh |
$193 26 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1123 INSTALL AUTOMATIC STACK DAMPER |
Savings: $409 Cost: $1,800 |
- | - | - | - | $409 | 53 | - | - |
- - kWh |
- - kW-months/year |
$409 53 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $149 Cost: $149 |
$149 | 4,196 | - | - | - | - | - | - |
$149 4,196 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $27,718 Cost: $58,387 |
$12,758 | 427,289 | $8,346 | 1,115 | $2,269 | 292 | $4,345 | 822,938 | $12,758 427,289 kWh |
$8,346 1,115 kW-months/year |
$2,269 292 MMBtu |
$4,345 822,938 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,716 Cost: $1,000 |
$2,268 | 76,082 | $1,588 | 212 | $1,860 | 240 | - | - | $2,268 76,082 kWh |
$1,588 212 kW-months/year |
$1,860 240 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |