Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2004
Principal Product Radiators and Intercoolers
NAICS 332410 - Power Boiler and Heat Exchanger Manufacturing
SIC 3443 - Fabricated Plate Work (boiler Shops)
Sales $10,000,000-$50,000,000
# of Employees 110
Plant Area (Sq.Ft.) 123,000
Annual Production 38,000 Pieces
Production Hrs. Annual 4,250
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $56,327 1,694,880 kWh $0.03
Electricity Demand $46,973 4,508 kW-months/year $10.42
Electricity Fees $18,255 - $ -
Natural Gas $163,019 21,983 MMBtu $7.42
TOTAL ENERGY COSTS $284,574
RECOMMENDED SAVINGS* $54,926 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $26,109
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$24,462
Cost:
$53,600
$13,564 384,264 $10,898 991 - - $13,564
384,264
kWh
$10,898
991
kW-months/year
-
-
MMBtu
02: 2.7314 REDUCE VENTILATION AIR Savings:
$16,661
Cost:
$32,000
- - - - $16,661 2,245 -
-
kWh
-
-
kW-months/year
$16,661
2,245
MMBtu
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$12,156
Cost:
$11,000
- - - - $12,156 1,638 -
-
kWh
-
-
kW-months/year
$12,156
1,638
MMBtu
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,028
Cost:
$100
- - - - $1,028 139 -
-
kWh
-
-
kW-months/year
$1,028
139
MMBtu
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$619
Cost:
$640
$323 9,154 $296 27 - - $323
9,154
kWh
$296
27
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$54,926
Cost:
$97,340
$13,887 393,418 $11,194 1,018 $29,845 4,022 $13,887
393,418
kWh
$11,194
1,018
kW-months/year
$29,845
4,022
MMBtu
TOTAL IMPLEMENTED Savings:
$26,109
Cost:
$54,340
$13,887 393,418 $11,194 1,018 $1,028 139 $13,887
393,418
kWh
$11,194
1,018
kW-months/year
$1,028
139
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas